Acute durability of cavotricuspid isthmus block after pulsed electric field ablation: randomized comparison of two pentaspline catheter configurations (SECTION trial)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085887" target="_blank" >RIV/00023001:_____/25:00085887 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60076658:12110/25:43910522 RIV/61988987:17110/25:A2603DG7 RIV/00216208:11110/25:10503232 RIV/00216208:11130/25:10503232 RIV/00064165:_____/25:10503232
Výsledek na webu
<a href="https://academic.oup.com/europace/article/27/10/euaf234/8262584" target="_blank" >https://academic.oup.com/europace/article/27/10/euaf234/8262584</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euaf234" target="_blank" >10.1093/europace/euaf234</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Acute durability of cavotricuspid isthmus block after pulsed electric field ablation: randomized comparison of two pentaspline catheter configurations (SECTION trial)
Popis výsledku v původním jazyce
Aims: Cavotricuspid isthmus (CTI) ablation is commonly performed alongside catheter ablation of atrial fibrillation (AF). However, the acute efficacy of the CTI ablation using the pentaspline catheter and pulsed electric field (PEF) energy has not been systematically evaluated. This randomized study assessed the acute efficacy and extent of haemolysis associated with CTI ablation when performed using two different configurations of the pentaspline catheter. Methods and results: A total of 178 patients (age 65 +/- 10 years, 66% of males) undergoing PEF ablation of the CTI in conjunction with AF ablation were randomly assigned to receive ablation using either the basket configuration (n = 95) or the flower configuration (n = 83) of the pentaspline catheter. The CTI ablation was performed before left atrial ablation. It was guided by intracardiac echocardiography, and bidirectional block was confirmed by pacing manoeuvres. Venous blood samples to assess haemolytic biomarkers were collected before and immediately after the CTI ablation. The groups were broadly comparable in baseline characteristics. The flower group demonstrated superior procedural efficiency, with fewer applications required to achieve a CTI block (3.4 +/- 3.1 vs. 8.0 +/- 4.1, P < 0.001), a shorter time to block (96 +/- 289 vs. 177 +/- 192 s, P < 0.001), and fewer total applications (10.1 +/- 3.4 vs. 13.3 +/- 5.1, P < 0.001). Acute reconduction occurred in 20% of cases overall, but was significantly lower in the flower group (6% vs. 32%, P < 0.001; hazard ratio: 0.14, 95% confidence interval: 0.06-0.40). Haemolysis was notably lower in the flower group, with significantly less post-procedural free haemoglobin (154 +/- 112 vs. 210 +/- 115 mg/L, P < 0.001). One case of transient ST elevations occurred in the flower group without clinical consequence. Conclusion: Pulsed electric field ablation of the CTI using the flower configuration of the pentaspline catheter demonstrated higher acute efficacy in achieving CTI block and a more favourable safety profile regarding haemolysis compared to the basket configuration. This is likely due to the larger footprint and improved tissue contact of all electrodes, minimizing the leakage of PEF energy into the blood pool. [GRAPHICS]
Název v anglickém jazyce
Acute durability of cavotricuspid isthmus block after pulsed electric field ablation: randomized comparison of two pentaspline catheter configurations (SECTION trial)
Popis výsledku anglicky
Aims: Cavotricuspid isthmus (CTI) ablation is commonly performed alongside catheter ablation of atrial fibrillation (AF). However, the acute efficacy of the CTI ablation using the pentaspline catheter and pulsed electric field (PEF) energy has not been systematically evaluated. This randomized study assessed the acute efficacy and extent of haemolysis associated with CTI ablation when performed using two different configurations of the pentaspline catheter. Methods and results: A total of 178 patients (age 65 +/- 10 years, 66% of males) undergoing PEF ablation of the CTI in conjunction with AF ablation were randomly assigned to receive ablation using either the basket configuration (n = 95) or the flower configuration (n = 83) of the pentaspline catheter. The CTI ablation was performed before left atrial ablation. It was guided by intracardiac echocardiography, and bidirectional block was confirmed by pacing manoeuvres. Venous blood samples to assess haemolytic biomarkers were collected before and immediately after the CTI ablation. The groups were broadly comparable in baseline characteristics. The flower group demonstrated superior procedural efficiency, with fewer applications required to achieve a CTI block (3.4 +/- 3.1 vs. 8.0 +/- 4.1, P < 0.001), a shorter time to block (96 +/- 289 vs. 177 +/- 192 s, P < 0.001), and fewer total applications (10.1 +/- 3.4 vs. 13.3 +/- 5.1, P < 0.001). Acute reconduction occurred in 20% of cases overall, but was significantly lower in the flower group (6% vs. 32%, P < 0.001; hazard ratio: 0.14, 95% confidence interval: 0.06-0.40). Haemolysis was notably lower in the flower group, with significantly less post-procedural free haemoglobin (154 +/- 112 vs. 210 +/- 115 mg/L, P < 0.001). One case of transient ST elevations occurred in the flower group without clinical consequence. Conclusion: Pulsed electric field ablation of the CTI using the flower configuration of the pentaspline catheter demonstrated higher acute efficacy in achieving CTI block and a more favourable safety profile regarding haemolysis compared to the basket configuration. This is likely due to the larger footprint and improved tissue contact of all electrodes, minimizing the leakage of PEF energy into the blood pool. [GRAPHICS]
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/LX22NPO5104" target="_blank" >LX22NPO5104: Národní institut pro výzkum metabolických a kardiovaskulárních onemocnění</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
1532-2092
Svazek periodika
27
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
"art. no. euaf234"
Kód UT WoS článku
001591064500001
EID výsledku v databázi Scopus
2-s2.0-105018344824