Novel heat exchanger in extracorporeal circuit: technical and biological feasibility
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085912" target="_blank" >RIV/00023001:_____/25:00085912 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/25:10504397
Výsledek na webu
<a href="https://www.nature.com/articles/s41598-025-20798-w#Fun" target="_blank" >https://www.nature.com/articles/s41598-025-20798-w#Fun</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-025-20798-w" target="_blank" >10.1038/s41598-025-20798-w</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Novel heat exchanger in extracorporeal circuit: technical and biological feasibility
Popis výsledku v původním jazyce
To evaluate a novel anticoagulation strategy in an extracorporeal circuit, we introduce a device that induces local hypothermia as blood flows through the circuit. Using a pig model, we assessed its technical feasibility, biocompatibility, and safety. Sixteen pigs were randomly assigned to either the cooled group or the control group and underwent midline laparotomy to establish extracorporeal circulation (blood flow 500 ml/min) via the caudal vena cava for up to four hours. Blood samples were collected at baseline and at 15, 60, and 240 min during the experiment. In the cooled group, blood was cooled to 20 degrees C and then rewarmed to 37 degrees C, while in the control group, blood was maintained at 37 degrees C. A total of 6 cooled and 4 control pigs completed 4 h of the experiment. Our findings confirm the technical feasibility of the proposed device, which effectively maintained the required temperature differentials while keeping the pressure differentials in the circuit within 150 mmHg. No issues with circuit patency were observed. Additionally, no adverse effects were detected on erythrocyte stability. Within the limitation of the short observation period, no adverse effects were observed on renal, liver, or cardiac function. Our data suggest that local hypothermia in the extracorporeal circuit may mitigate surgery-induced inflammation.
Název v anglickém jazyce
Novel heat exchanger in extracorporeal circuit: technical and biological feasibility
Popis výsledku anglicky
To evaluate a novel anticoagulation strategy in an extracorporeal circuit, we introduce a device that induces local hypothermia as blood flows through the circuit. Using a pig model, we assessed its technical feasibility, biocompatibility, and safety. Sixteen pigs were randomly assigned to either the cooled group or the control group and underwent midline laparotomy to establish extracorporeal circulation (blood flow 500 ml/min) via the caudal vena cava for up to four hours. Blood samples were collected at baseline and at 15, 60, and 240 min during the experiment. In the cooled group, blood was cooled to 20 degrees C and then rewarmed to 37 degrees C, while in the control group, blood was maintained at 37 degrees C. A total of 6 cooled and 4 control pigs completed 4 h of the experiment. Our findings confirm the technical feasibility of the proposed device, which effectively maintained the required temperature differentials while keeping the pressure differentials in the circuit within 150 mmHg. No issues with circuit patency were observed. Additionally, no adverse effects were detected on erythrocyte stability. Within the limitation of the short observation period, no adverse effects were observed on renal, liver, or cardiac function. Our data suggest that local hypothermia in the extracorporeal circuit may mitigate surgery-induced inflammation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10700 - Other natural sciences
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific reports
ISSN
2045-2322
e-ISSN
2045-2322
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
"art. no. 36864"
Kód UT WoS článku
001600059400011
EID výsledku v databázi Scopus
2-s2.0-105019540054