The Impact of Connective Tissue Disorders on Patients with Thoracic Aortic Pseudoaneurysms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00086103" target="_blank" >RIV/00023001:_____/25:00086103 - isvavai.cz</a>
Výsledek na webu
<a href="https://reference-global.com/article/10.2478/jce-2025-0019" target="_blank" >https://reference-global.com/article/10.2478/jce-2025-0019</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/jce-2025-0019" target="_blank" >10.2478/jce-2025-0019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Impact of Connective Tissue Disorders on Patients with Thoracic Aortic Pseudoaneurysms
Popis výsledku v původním jazyce
Introduction We sought to review the clinical presentation, etiologies, diagnostic methods, surgical techniques, and long-term outcomes of patients with thoracic aortic false aneurysms (TAFA) treated at our institution. Although connective tissue disorders (CTDs) are recognized risk factors for aortic aneurysms, their role in the development and management of false aneurysms is less well established. The aim of this study was to compare cohorts of patients with and without CTD.Methods A total of 116 patients were diagnosed with a thoracic aortic pseudoaneurysm between January 1996 and August 2024 at our institute. Genetic screening confirmed a CTD in 18 patients. Follow-up was obtained for all patients through echocardiographic or computed tomography assessment.Results In all cases, TAFA developed after prior cardiovascular surgery. In the CTD cohort, the most common initial diagnosis was aortic dissection (72%), and the most frequent primary operation was the Bentall procedure (88%). Ten patients with CTD were indicated for reintervention (surgical reoperation, endoluminal graft implantation, or occluder implantation).Conclusion One-year survival was higher in patients without CTD (98%) than in those with CTD (89%); however, ten-year survival was higher in the CTD cohort (89% vs. 68%). After surgical reoperation, secondary TAFA recurrence was lower in patients without CTD (16% vs. 22%), although recurrence occurred sooner in this group. Operative mortality was 11.1% in patients with CTD and 5.1% in those without CTD.
Název v anglickém jazyce
The Impact of Connective Tissue Disorders on Patients with Thoracic Aortic Pseudoaneurysms
Popis výsledku anglicky
Introduction We sought to review the clinical presentation, etiologies, diagnostic methods, surgical techniques, and long-term outcomes of patients with thoracic aortic false aneurysms (TAFA) treated at our institution. Although connective tissue disorders (CTDs) are recognized risk factors for aortic aneurysms, their role in the development and management of false aneurysms is less well established. The aim of this study was to compare cohorts of patients with and without CTD.Methods A total of 116 patients were diagnosed with a thoracic aortic pseudoaneurysm between January 1996 and August 2024 at our institute. Genetic screening confirmed a CTD in 18 patients. Follow-up was obtained for all patients through echocardiographic or computed tomography assessment.Results In all cases, TAFA developed after prior cardiovascular surgery. In the CTD cohort, the most common initial diagnosis was aortic dissection (72%), and the most frequent primary operation was the Bentall procedure (88%). Ten patients with CTD were indicated for reintervention (surgical reoperation, endoluminal graft implantation, or occluder implantation).Conclusion One-year survival was higher in patients without CTD (98%) than in those with CTD (89%); however, ten-year survival was higher in the CTD cohort (89% vs. 68%). After surgical reoperation, secondary TAFA recurrence was lower in patients without CTD (16% vs. 22%), although recurrence occurred sooner in this group. Operative mortality was 11.1% in patients with CTD and 5.1% in those without CTD.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of cardiovascular emergencies
ISSN
2457-5518
e-ISSN
2457-550X
Svazek periodika
11
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
8
Strana od-do
148-155
Kód UT WoS článku
001651118700006
EID výsledku v databázi Scopus
—