Evaluation of the short-term host response and biomechanics of an absorbable poly-4-hydroxybutyrate scaffold in a sheep model following vaginal implantation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023698%3A_____%2F22%3AN0000005" target="_blank" >RIV/00023698:_____/22:N0000005 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/22:43922665
Výsledek na webu
<a href="https://obgyn.onlinelibrary.wiley.com/doi/full/10.1111/1471-0528.17040" target="_blank" >https://obgyn.onlinelibrary.wiley.com/doi/full/10.1111/1471-0528.17040</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/1471-0528.17040" target="_blank" >10.1111/1471-0528.17040</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of the short-term host response and biomechanics of an absorbable poly-4-hydroxybutyrate scaffold in a sheep model following vaginal implantation
Popis výsledku v původním jazyce
Objective To evaluate the host- and biomechanical response to a fully absorbable poly-4-hydroxybutyrate (P4HB) scaffold in comparison with the response to polypropylene (PP) mesh. Design In vivo animal experiment. Setting KU Leuven Center for Surgical Technologies. Population Fourteen parous female Mule sheep. Methods P4HB scaffolds were surgically implanted in the posterior vaginal wall of sheep. The comparative PP mesh data were obtained from an identical study protocol performed previously. Main outcome measures Gross necropsy, host response and biomechanical evaluation of explants, and the in vivo P4HB scaffold degradation were evaluated at 60- and 180-days post-implantation. Data are reported as mean +/- standard deviation (SD) or standard error of the mean (SEM). Results Gross necropsy revealed no implant-related adverse events using P4HB scaffolds. The tensile stiffness of the P4HB explants increased at 180-days (12.498 +/- 2.66 N/mm SEM [p =0.019]) as compared to 60-days (4.585 +/- 1.57 N/mm) post-implantation, while P4HB degraded gradually. P4HB scaffolds exhibited excellent tissue integration with dense connective tissue and a moderate initial host response. P4HB scaffolds induced a significantly higher M2/M1 ratio (1.70 +/- 0.67 SD, score 0-4), as compared to PP mesh(0.99 +/- 0.78 SD, score 0-4) at 180-days. Conclusions P4HB scaffold facilitated a gradual load transfer to vaginal tissue over time. The fully absorbable P4HB scaffold, in comparison to PP mesh, has a favorable host response with comparable load-bearing capacity. If these results are also observed at longer follow-up in-vivo, a clinical study using P4HB for vaginal POP surgery may be warranted to demonstrate efficacy.
Název v anglickém jazyce
Evaluation of the short-term host response and biomechanics of an absorbable poly-4-hydroxybutyrate scaffold in a sheep model following vaginal implantation
Popis výsledku anglicky
Objective To evaluate the host- and biomechanical response to a fully absorbable poly-4-hydroxybutyrate (P4HB) scaffold in comparison with the response to polypropylene (PP) mesh. Design In vivo animal experiment. Setting KU Leuven Center for Surgical Technologies. Population Fourteen parous female Mule sheep. Methods P4HB scaffolds were surgically implanted in the posterior vaginal wall of sheep. The comparative PP mesh data were obtained from an identical study protocol performed previously. Main outcome measures Gross necropsy, host response and biomechanical evaluation of explants, and the in vivo P4HB scaffold degradation were evaluated at 60- and 180-days post-implantation. Data are reported as mean +/- standard deviation (SD) or standard error of the mean (SEM). Results Gross necropsy revealed no implant-related adverse events using P4HB scaffolds. The tensile stiffness of the P4HB explants increased at 180-days (12.498 +/- 2.66 N/mm SEM [p =0.019]) as compared to 60-days (4.585 +/- 1.57 N/mm) post-implantation, while P4HB degraded gradually. P4HB scaffolds exhibited excellent tissue integration with dense connective tissue and a moderate initial host response. P4HB scaffolds induced a significantly higher M2/M1 ratio (1.70 +/- 0.67 SD, score 0-4), as compared to PP mesh(0.99 +/- 0.78 SD, score 0-4) at 180-days. Conclusions P4HB scaffold facilitated a gradual load transfer to vaginal tissue over time. The fully absorbable P4HB scaffold, in comparison to PP mesh, has a favorable host response with comparable load-bearing capacity. If these results are also observed at longer follow-up in-vivo, a clinical study using P4HB for vaginal POP surgery may be warranted to demonstrate efficacy.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30214 - Obstetrics and gynaecology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY
ISSN
1470-0328
e-ISSN
1471-0528
Svazek periodika
129
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
1039-1049
Kód UT WoS článku
000736079400001
EID výsledku v databázi Scopus
2-s2.0-85122006173