Three-Dimensional Transperineal Ultrasound Assessment of the Anal Sphincter Immediately After Vaginal Birth: An Exploratory Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023698%3A_____%2F24%3AN0000005" target="_blank" >RIV/00023698:_____/24:N0000005 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/24:43927185
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/jum.16490" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/jum.16490</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jum.16490" target="_blank" >10.1002/jum.16490</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Three-Dimensional Transperineal Ultrasound Assessment of the Anal Sphincter Immediately After Vaginal Birth: An Exploratory Study
Popis výsledku v původním jazyce
ObjectivesTo assess the feasibility of acquiring adequate transperineal ultrasound (TPUS) volumes of the anal sphincter (AS) immediately after vaginal birth, the reproducibility of its measurements, and detecting defects therein.MethodsSecondary analysis of TPUS volumes of the AS, acquired immediately after vaginal birth with a transversely oriented convex probe. Two independent experts ranked off-line image quality as "inadequate," "adequate," or "ideal" using the Point-of-Care Ultrasound Image Quality scale. On "adequate" and "ideal" quality volumes, the length of the external AS at 6 and 12 o'clock, and the volume of the external and internal AS were measured. Additionally, volumes were screened for AS defects on tomographic ultrasound imaging. Subsequently, we rated the intra- and interrater agreement on those findings.ResultsOf 183 volumes, 162 were considered "adequate" or of "ideal" quality (88.5%). Reasons for "inadequacy" were shadow artifacts (16/21), poor resolution (3/21), incomplete acquisition (1/21), or aberrant AS morphology (1/21). The intrarater reliability of two-dimensional (2D) and three-dimensional (3D) measurements was excellent, whereas interrater reliability was fair to good for 2D measurements and good for 3D measurements. In those tomographic ultrasound imaging (TUI) sequences including AS defects, the intra- and interrater reliability of the defect measurement were excellent [intraclass correlation coefficient (ICC) = 0.92 (0.80-0.94)] and moderate [ICC = 0.72 (0.63-0.79)]. In this cohort, there were only few (4/48; 8.3%) AS defects. However, grading them was poorly reproducible between experts.ConclusionTPUS of the AS immediately after vaginal birth yields adequate image quality and allows for reproducible measurements. In the few patients with AS defects, there was good agreement on the presence, but it was poor for the extent of defects.
Název v anglickém jazyce
Three-Dimensional Transperineal Ultrasound Assessment of the Anal Sphincter Immediately After Vaginal Birth: An Exploratory Study
Popis výsledku anglicky
ObjectivesTo assess the feasibility of acquiring adequate transperineal ultrasound (TPUS) volumes of the anal sphincter (AS) immediately after vaginal birth, the reproducibility of its measurements, and detecting defects therein.MethodsSecondary analysis of TPUS volumes of the AS, acquired immediately after vaginal birth with a transversely oriented convex probe. Two independent experts ranked off-line image quality as "inadequate," "adequate," or "ideal" using the Point-of-Care Ultrasound Image Quality scale. On "adequate" and "ideal" quality volumes, the length of the external AS at 6 and 12 o'clock, and the volume of the external and internal AS were measured. Additionally, volumes were screened for AS defects on tomographic ultrasound imaging. Subsequently, we rated the intra- and interrater agreement on those findings.ResultsOf 183 volumes, 162 were considered "adequate" or of "ideal" quality (88.5%). Reasons for "inadequacy" were shadow artifacts (16/21), poor resolution (3/21), incomplete acquisition (1/21), or aberrant AS morphology (1/21). The intrarater reliability of two-dimensional (2D) and three-dimensional (3D) measurements was excellent, whereas interrater reliability was fair to good for 2D measurements and good for 3D measurements. In those tomographic ultrasound imaging (TUI) sequences including AS defects, the intra- and interrater reliability of the defect measurement were excellent [intraclass correlation coefficient (ICC) = 0.92 (0.80-0.94)] and moderate [ICC = 0.72 (0.63-0.79)]. In this cohort, there were only few (4/48; 8.3%) AS defects. However, grading them was poorly reproducible between experts.ConclusionTPUS of the AS immediately after vaginal birth yields adequate image quality and allows for reproducible measurements. In the few patients with AS defects, there was good agreement on the presence, but it was poor for the extent of defects.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30214 - Obstetrics and gynaecology
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF ULTRASOUND IN MEDICINE
ISSN
0278-4297
e-ISSN
1550-9613
Svazek periodika
43
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
1673-1681
Kód UT WoS článku
001244589700001
EID výsledku v databázi Scopus
2-s2.0-85195999295