Digital PCR can provide improved BCR-ABL1 detection in chronic myeloid leukemia patients in deep molecular response and sensitivity of standard quantitative methods using EAC assays
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023736%3A_____%2F21%3A00013224" target="_blank" >RIV/00023736:_____/21:00013224 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/65269705:_____/21:00074218 RIV/00216224:14740/21:00120108
Výsledek na webu
<a href="https://doi.org/10.1016/j.plabm.2021.e00210" target="_blank" >https://doi.org/10.1016/j.plabm.2021.e00210</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.plabm.2021.e00210" target="_blank" >10.1016/j.plabm.2021.e00210</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Digital PCR can provide improved BCR-ABL1 detection in chronic myeloid leukemia patients in deep molecular response and sensitivity of standard quantitative methods using EAC assays
Popis výsledku v původním jazyce
BCR-ABL1 molecular detection using quantitative PCR (qPCR) methods is the golden standard of chronic myeloid leukemia (CML) monitoring. However, due to variable sensitivity of qPCR assays across laboratories, alternative methods are tested. Digital PCR (dPCR) has been suggested as a robust and reproducible option. Here we present a comparison of droplet dPCR with routinely used reverse-transcription qPCR (RT-qPCR) and automated GeneXpert systems. Detection limit of dPCR was above 3 BCR-ABL1 copies, although due to background amplification the resulting sensitivity was 0.01% BCR-ABL1 (MR4.0). Nevertheless, in comparison with GeneXpert, dPCR categorized more than 50% of the patients into different MR groups, showing a potential for improved BCR-ABL1 detection.
Název v anglickém jazyce
Digital PCR can provide improved BCR-ABL1 detection in chronic myeloid leukemia patients in deep molecular response and sensitivity of standard quantitative methods using EAC assays
Popis výsledku anglicky
BCR-ABL1 molecular detection using quantitative PCR (qPCR) methods is the golden standard of chronic myeloid leukemia (CML) monitoring. However, due to variable sensitivity of qPCR assays across laboratories, alternative methods are tested. Digital PCR (dPCR) has been suggested as a robust and reproducible option. Here we present a comparison of droplet dPCR with routinely used reverse-transcription qPCR (RT-qPCR) and automated GeneXpert systems. Detection limit of dPCR was above 3 BCR-ABL1 copies, although due to background amplification the resulting sensitivity was 0.01% BCR-ABL1 (MR4.0). Nevertheless, in comparison with GeneXpert, dPCR categorized more than 50% of the patients into different MR groups, showing a potential for improved BCR-ABL1 detection.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30205 - Hematology
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-30397A" target="_blank" >NV17-30397A: Mutační analýza primitivních buněčných populací u chronické myeloidní leukémie: za hranicí BCR-ABL1</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Practical laboratory medicine
ISSN
2352-5517
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
[May]
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
"art. no. e00210"
Kód UT WoS článku
000653682600011
EID výsledku v databázi Scopus
2-s2.0-85102511335