A functional assay for the determination of heparin-induced thrombocytopenia via flow cytometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023736%3A_____%2F23%3A00013570" target="_blank" >RIV/00023736:_____/23:00013570 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00843989:_____/23:E0110427
Výsledek na webu
<a href="https://doi.org/10.3390/diagnostics13183019" target="_blank" >https://doi.org/10.3390/diagnostics13183019</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics13183019" target="_blank" >10.3390/diagnostics13183019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A functional assay for the determination of heparin-induced thrombocytopenia via flow cytometry
Popis výsledku v původním jazyce
Heparin-induced thrombocytopenia (HIT) is a life-threatening complication of heparin therapy (both unfractionated heparin and low-molecular-weight heparin). In our study, we examined a group of 122 patients with suspected HIT. The samples of all patients were analyzed in the first step using an immunoassay (ID-PaGIA Heparin/PF4, Hemos1L-Acustar HIT IgG, ZYMUTEST HIA Monostrip IgG) to detect the presence of antibodies against heparin–PF4 complexes (platelet factor 4). When the immunoassay was positive, the sample was subsequently analyzed for HIT with a functional flow cytometry assay, the HITAlert kit, the purpose of which was to demonstrate the ability of the antibodies present to activate platelets. A diagnosis of HIT can be made only after a positive functional test result. In this article, we present an overview of our practical experience with the use of the new functional method of analysis, HIT, with flow cytometry. In this work, we compared the mutual sensitivity of two functional tests, SRA and the flow cytometry HITAlert kit, in patients perceived as being at risk for HIT. This work aims to delineate the principle, procedure, advantages, pitfalls, and possibilities of the application of the functional test HITAlert using flow cytometry.
Název v anglickém jazyce
A functional assay for the determination of heparin-induced thrombocytopenia via flow cytometry
Popis výsledku anglicky
Heparin-induced thrombocytopenia (HIT) is a life-threatening complication of heparin therapy (both unfractionated heparin and low-molecular-weight heparin). In our study, we examined a group of 122 patients with suspected HIT. The samples of all patients were analyzed in the first step using an immunoassay (ID-PaGIA Heparin/PF4, Hemos1L-Acustar HIT IgG, ZYMUTEST HIA Monostrip IgG) to detect the presence of antibodies against heparin–PF4 complexes (platelet factor 4). When the immunoassay was positive, the sample was subsequently analyzed for HIT with a functional flow cytometry assay, the HITAlert kit, the purpose of which was to demonstrate the ability of the antibodies present to activate platelets. A diagnosis of HIT can be made only after a positive functional test result. In this article, we present an overview of our practical experience with the use of the new functional method of analysis, HIT, with flow cytometry. In this work, we compared the mutual sensitivity of two functional tests, SRA and the flow cytometry HITAlert kit, in patients perceived as being at risk for HIT. This work aims to delineate the principle, procedure, advantages, pitfalls, and possibilities of the application of the functional test HITAlert using flow cytometry.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30205 - Hematology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Diagnostics
ISSN
2075-4418
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
18
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
13
Strana od-do
"art. no. 3019"
Kód UT WoS článku
001073307400001
EID výsledku v databázi Scopus
2-s2.0-85172227086