Electromagnetic Modeling of Rat’s Head: Comparison of Formulations and Models
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023752%3A_____%2F19%3A43920047" target="_blank" >RIV/00023752:_____/19:43920047 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/19:PU133156
Výsledek na webu
<a href="https://www.radioeng.cz/fulltexts/2019/19_03_0517_0527.pdf" target="_blank" >https://www.radioeng.cz/fulltexts/2019/19_03_0517_0527.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.13164/re.2019.0517" target="_blank" >10.13164/re.2019.0517</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electromagnetic Modeling of Rat’s Head: Comparison of Formulations and Models
Popis výsledku v původním jazyce
Reliable inverse imaging of source currents in rat’s brain requires sufficiently accurate and CPU-time moderate forward models of fields to calibrate inverse solvers. In this paper, we compare different mathematical formulations of the electromagnetic problem related to the analysis of brain waves (static, quasi-static, full-wave) and various meshes differing in the density, the type and the geometrical accuracy. A sufficiently accurate model of brain waves is then completed by the cerebrospinal fluid and the skull. The resultant composite model of rat’s head with properly set electrical parameters has to be calibrated by the outputs of measurements. That way, a realistic electromagnetic model of the head of a live rat can be obtained.
Název v anglickém jazyce
Electromagnetic Modeling of Rat’s Head: Comparison of Formulations and Models
Popis výsledku anglicky
Reliable inverse imaging of source currents in rat’s brain requires sufficiently accurate and CPU-time moderate forward models of fields to calibrate inverse solvers. In this paper, we compare different mathematical formulations of the electromagnetic problem related to the analysis of brain waves (static, quasi-static, full-wave) and various meshes differing in the density, the type and the geometrical accuracy. A sufficiently accurate model of brain waves is then completed by the cerebrospinal fluid and the skull. The resultant composite model of rat’s head with properly set electrical parameters has to be calibrated by the outputs of measurements. That way, a realistic electromagnetic model of the head of a live rat can be obtained.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radioengineering
ISSN
1210-2512
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
517-527
Kód UT WoS článku
000485877700004
EID výsledku v databázi Scopus
2-s2.0-85076685452