Popis výsledku v původním jazyce
Oronasal thermal sensor signal recording within sleeping period was analyzed in sense of detection of respiratory events. The goal was to evaluate what extent an up to date nonlinear dimension reduction technique increases performance of apnea classification compared to classifications based on linear dimension reduction and raw data. Based on an extensive database of recordings in apneic patients, we concluded that a non-linear approach didn't lead to better classification performance in comparison with a linear decomposition technique. We suggested, that it was due to the signal amplitude is naturally the main feature of respiratory events. However, nonlinear methods do not naturally maintain the amplitude based structure in data. Due to this fact we get the worse signal representation in comparison with linear methods.
Název v anglickém jazyce
Comparison of Linear and Non-linear Dimension Reduction Techniques for Automatic Apnea Detection
Popis výsledku anglicky
Oronasal thermal sensor signal recording within sleeping period was analyzed in sense of detection of respiratory events. The goal was to evaluate what extent an up to date nonlinear dimension reduction technique increases performance of apnea classification compared to classifications based on linear dimension reduction and raw data. Based on an extensive database of recordings in apneic patients, we concluded that a non-linear approach didn't lead to better classification performance in comparison with a linear decomposition technique. We suggested, that it was due to the signal amplitude is naturally the main feature of respiratory events. However, nonlinear methods do not naturally maintain the amplitude based structure in data. Due to this fact we get the worse signal representation in comparison with linear methods.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2019 7th E-Health and Bioengineering Conference, EHB 2019
ISBN
978-1-72812-603-6
ISSN
—
e-ISSN
2575-5145
Počet stran výsledku
4
Strana od-do
"Article number 8969972"
Název nakladatele
IEEE Xplore
Místo vydání
online
Místo konání akce
Lasi, Romania
Datum konání akce
21. 11. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—