Assessment of radiochromic gel dosimeter based on Turnbull Blue dye for relative output factor measurements of the Leksell Gamma Knife® PerfexionTM
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F12%3A00006247" target="_blank" >RIV/00023884:_____/12:00006247 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1742-6596/573/1/012049" target="_blank" >http://dx.doi.org/10.1088/1742-6596/573/1/012049</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/573/1/012049" target="_blank" >10.1088/1742-6596/573/1/012049</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of radiochromic gel dosimeter based on Turnbull Blue dye for relative output factor measurements of the Leksell Gamma Knife® PerfexionTM
Popis výsledku v původním jazyce
The aim of the study was to perform assessment of radiochromic gel dosimeter based on Turnbull blue dye formed by irradiation (TB gel dosimeter) for measurement of ROFs for 4 mm and 8 mm collimators for the Leksell Gamma Knife PerfexionTM. All measurements have been carried out using home-made spherical Perspex glass phantom of diameter 160 mm. TB gel dosimeters were scanned using homemade optical CT scanner. The results are compared with vendor recommended Monte Carlo calculated ROFs values of 0.814 and 0.900 for 4 mm and 8 mm collimators, respectively. The comparisons between the gel measurements and the treatment planning system (TPS) calculation are presented in the form of 2D isodoses for the central slices and 1D profile. Measured ROF 0.746 and 0.874 for 4 mm and 8 mm collimators respectively are in a reasonable agreement with vendor recommended values and measured relative dose distribution in a central slice and measured profiles of all shots show excellent correspondence with TPS.
Název v anglickém jazyce
Assessment of radiochromic gel dosimeter based on Turnbull Blue dye for relative output factor measurements of the Leksell Gamma Knife® PerfexionTM
Popis výsledku anglicky
The aim of the study was to perform assessment of radiochromic gel dosimeter based on Turnbull blue dye formed by irradiation (TB gel dosimeter) for measurement of ROFs for 4 mm and 8 mm collimators for the Leksell Gamma Knife PerfexionTM. All measurements have been carried out using home-made spherical Perspex glass phantom of diameter 160 mm. TB gel dosimeters were scanned using homemade optical CT scanner. The results are compared with vendor recommended Monte Carlo calculated ROFs values of 0.814 and 0.900 for 4 mm and 8 mm collimators, respectively. The comparisons between the gel measurements and the treatment planning system (TPS) calculation are presented in the form of 2D isodoses for the central slices and 1D profile. Measured ROF 0.746 and 0.874 for 4 mm and 8 mm collimators respectively are in a reasonable agreement with vendor recommended values and measured relative dose distribution in a central slice and measured profiles of all shots show excellent correspondence with TPS.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Physics: Conference Series
ISSN
1742-6596
e-ISSN
—
Svazek periodika
573
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
UG - Ugandská republika
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000352600500049
EID výsledku v databázi Scopus
—