5-Year Outcomes After Left Atrial Appendage Closure From the PREVAIL and PROTECT AF Trials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F12%3A00007391" target="_blank" >RIV/00023884:_____/12:00007391 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jacc.2017.10.021" target="_blank" >http://dx.doi.org/10.1016/j.jacc.2017.10.021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacc.2017.10.021" target="_blank" >10.1016/j.jacc.2017.10.021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
5-Year Outcomes After Left Atrial Appendage Closure From the PREVAIL and PROTECT AF Trials
Popis výsledku v původním jazyce
The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, St. Paul, Minnesota) was equivalent to warfarin for preventing stroke in atrial fibrillation, but had a high rate of complications. In a second randomized trial, PREVAIL (Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy), the complication rate was low. The warfarin cohort experienced an unexpectedly low ischemic stroke rate, rendering the efficacy endpoints inconclusive. However, these outcomes were based on relatively few patients followed for a relatively short time.
Název v anglickém jazyce
5-Year Outcomes After Left Atrial Appendage Closure From the PREVAIL and PROTECT AF Trials
Popis výsledku anglicky
The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) trial demonstrated that left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, St. Paul, Minnesota) was equivalent to warfarin for preventing stroke in atrial fibrillation, but had a high rate of complications. In a second randomized trial, PREVAIL (Evaluation of the WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy), the complication rate was low. The warfarin cohort experienced an unexpectedly low ischemic stroke rate, rendering the efficacy endpoints inconclusive. However, these outcomes were based on relatively few patients followed for a relatively short time.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the American College of Cardiology
ISSN
0735-1097
e-ISSN
—
Svazek periodika
70
Číslo periodika v rámci svazku
24
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
2964-2975
Kód UT WoS článku
000418262500003
EID výsledku v databázi Scopus