Leadless Cardiac Pacemakers Back to the Future
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F15%3A00007808" target="_blank" >RIV/00023884:_____/15:00007808 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jacc.2015.06.1081" target="_blank" >http://dx.doi.org/10.1016/j.jacc.2015.06.1081</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacc.2015.06.1081" target="_blank" >10.1016/j.jacc.2015.06.1081</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Leadless Cardiac Pacemakers Back to the Future
Popis výsledku v původním jazyce
Despite significant advances in battery longevity, lead performance, and programming features since the first implanted permanent pacemaker was developed, the basic design of cardiac pacemakers has remained relatively unchanged over the past 50 years. Because of inherent limitations in their design, conventional (transvenous) pacemakers are prone to multiple potential short-and long-term complications. Accordingly, there has been intense interest in a system able to provide the symptomatic and potentially lifesaving therapies of cardiac pacemakers while mitigating many of the risks associated with their weakest link-the transvenous lead. Leadless cardiac pacing represents the future of cardiac pacing systems, similar to the transition that occurred from the use of epicardial pacing systems to the familiar transvenous systems of today. This review summarizes the current evidence and potential benefits of leadless pacing systems, which are either commercially available (in Europe) or under clinical investigation. (C) 2015 by the American College of Cardiology Foundation.
Název v anglickém jazyce
Leadless Cardiac Pacemakers Back to the Future
Popis výsledku anglicky
Despite significant advances in battery longevity, lead performance, and programming features since the first implanted permanent pacemaker was developed, the basic design of cardiac pacemakers has remained relatively unchanged over the past 50 years. Because of inherent limitations in their design, conventional (transvenous) pacemakers are prone to multiple potential short-and long-term complications. Accordingly, there has been intense interest in a system able to provide the symptomatic and potentially lifesaving therapies of cardiac pacemakers while mitigating many of the risks associated with their weakest link-the transvenous lead. Leadless cardiac pacing represents the future of cardiac pacing systems, similar to the transition that occurred from the use of epicardial pacing systems to the familiar transvenous systems of today. This review summarizes the current evidence and potential benefits of leadless pacing systems, which are either commercially available (in Europe) or under clinical investigation. (C) 2015 by the American College of Cardiology Foundation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the American College of Cardiology
ISSN
0735-1097
e-ISSN
—
Svazek periodika
66
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
1179-1189
Kód UT WoS článku
000360367600012
EID výsledku v databázi Scopus
2-s2.0-84940510732