Název v původním jazyce
Primary safety results from the LEADLESS Observational Study
Popis výsledku v původním jazyce
Aims A prospective, single-arm, multicentre, post-market study was conducted to confirm the short-term safety of the Nanostim (TM) leadless pacemaker (LP). In this study, we report the primary results of the LEADLESS Observational Study. Methods and results Subjects meeting VVIR pacemaker indications were enrolled and followed up after successful LP implantation, prior to discharge and post-implantation at 90 days, 180 days, and every 6 months thereafter for the assessment of adverse events. The primary safety endpoint was evaluated in terms of freedom from serious adverse device effects (SADEs) at 6 months in 300 subjects. Data for all enrolled subjects were also presented. A total of 470 subjects were enrolled (75.8 +/- 13.1 years, 62.8% male). The study paused in April 2014 following the occurrence of perforation events that led to changes in the protocol and investigator training. Freedom from SADEs, evaluated in 300 subjects enrolled post-pause, was 94.6% (95% confidence interval 91.0-97.2%) and demonstrated non-inferiority to a performance goal of 86% (P < 0.0001). Eighteen SADEs were observed in 16 (5.3%) subjects. The most frequently occurring events were cardiac perforation (1.3%), device dislodgement (0.3%), and vascular complications (1.3%). In the 470 subjects, 34 similar SADEs were observed in 31 (6.6%) subjects. After stratifying the results in relation to the study pause, there was a statistically significant difference in the final LP location (septum vs. apex) (P < 0.0001) and the number of repositioning attempts (< 2 vs. >= 2) (P = 0.05) and a decreasing trend in the rates of cardiac perforation and device dislodgement. Conclusion The primary safety endpoint at 6 months was successfully met for the Nanostim LP. The occurrence of cardiac perforation and device dislodgement declined after changes following the study pause.
Název v anglickém jazyce
Primary safety results from the LEADLESS Observational Study
Popis výsledku anglicky
Aims A prospective, single-arm, multicentre, post-market study was conducted to confirm the short-term safety of the Nanostim (TM) leadless pacemaker (LP). In this study, we report the primary results of the LEADLESS Observational Study. Methods and results Subjects meeting VVIR pacemaker indications were enrolled and followed up after successful LP implantation, prior to discharge and post-implantation at 90 days, 180 days, and every 6 months thereafter for the assessment of adverse events. The primary safety endpoint was evaluated in terms of freedom from serious adverse device effects (SADEs) at 6 months in 300 subjects. Data for all enrolled subjects were also presented. A total of 470 subjects were enrolled (75.8 +/- 13.1 years, 62.8% male). The study paused in April 2014 following the occurrence of perforation events that led to changes in the protocol and investigator training. Freedom from SADEs, evaluated in 300 subjects enrolled post-pause, was 94.6% (95% confidence interval 91.0-97.2%) and demonstrated non-inferiority to a performance goal of 86% (P < 0.0001). Eighteen SADEs were observed in 16 (5.3%) subjects. The most frequently occurring events were cardiac perforation (1.3%), device dislodgement (0.3%), and vascular complications (1.3%). In the 470 subjects, 34 similar SADEs were observed in 31 (6.6%) subjects. After stratifying the results in relation to the study pause, there was a statistically significant difference in the final LP location (septum vs. apex) (P < 0.0001) and the number of repositioning attempts (< 2 vs. >= 2) (P = 0.05) and a decreasing trend in the rates of cardiac perforation and device dislodgement. Conclusion The primary safety endpoint at 6 months was successfully met for the Nanostim LP. The occurrence of cardiac perforation and device dislodgement declined after changes following the study pause.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1491-1497
Kód UT WoS článku
000444551400019
EID výsledku v databázi Scopus
2-s2.0-85052564211