Targeting Nonpulmonary Vein Sources in Persistent Atrial Fibrillation Identified by Noncontact Charge Density Mapping UNCOVER AF Trial
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F19%3A00008258" target="_blank" >RIV/00023884:_____/19:00008258 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pubmed/31242746" target="_blank" >https://www.ncbi.nlm.nih.gov/pubmed/31242746</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.119.007233" target="_blank" >10.1161/CIRCEP.119.007233</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Targeting Nonpulmonary Vein Sources in Persistent Atrial Fibrillation Identified by Noncontact Charge Density Mapping UNCOVER AF Trial
Popis výsledku v původním jazyce
Background Identification and elimination of nonpulmonary vein targets may improve clinical outcomes in patients with persistent atrial fibrillation (AF). We report on the use of a novel, noncontact imaging and mapping system that uses ultrasound to reconstruct atrial chamber anatomy and measures timing and density of dipolar, ionic activation (ie, charge density) across the myocardium to guide ablation of atrial arrhythmias. Methods The prospective, nonrandomized UNCOVER AF trial (Utilizing Novel Dipole Density Capabilities to Objectively Visualize the Etiology of Rhythms in Atrial Fibrillation) was conducted at 13 centers across Europe and Canada. Patients with persistent AF (>7 days, <1 year) aged 18 to 80 years, scheduled for de novo catheter ablation, were eligible. Before pulmonary vein isolation, AF was mapped and then iteratively remapped to guide each subsequent ablation of charge density-identified targets. AF recurrence was evaluated at 3, 6, 9, and 12 months using continuous 24-hour ECG monitors. The primary effectiveness outcome was freedom from AF >30 seconds at 12 months for a single procedure with a secondary outcome being acute procedural efficacy. The primary safety outcome was freedom from device/procedure-related major adverse events. Results Between October 2016 and April 2017, 129 patients were enrolled, and 127 underwent mapping and catheter ablation. Acute procedural efficacy was demonstrated in 125 patients (98%). At 12 months, single procedure freedom from AF on or off antiarrhythmic drugs was 72.5% (95% CI, 63.9%-80.3%). After 1 or 2 procedures, freedom from AF was 93.2% (95% CI, 87.1%-97.0%). A total of 29 (23%) retreatments because of arrhythmia recurrence were performed with average time from index procedure to first retreatment being 7 months. The primary safety outcome was 98% with no device-related major adverse events reported. Conclusions This novel ultrasound imaging and charge density mapping system safely guided ablation of nonpulmonary vein targets in persistent AF patients with 73% single procedure and 93% second procedure freedom from AF at 12 months.
Název v anglickém jazyce
Targeting Nonpulmonary Vein Sources in Persistent Atrial Fibrillation Identified by Noncontact Charge Density Mapping UNCOVER AF Trial
Popis výsledku anglicky
Background Identification and elimination of nonpulmonary vein targets may improve clinical outcomes in patients with persistent atrial fibrillation (AF). We report on the use of a novel, noncontact imaging and mapping system that uses ultrasound to reconstruct atrial chamber anatomy and measures timing and density of dipolar, ionic activation (ie, charge density) across the myocardium to guide ablation of atrial arrhythmias. Methods The prospective, nonrandomized UNCOVER AF trial (Utilizing Novel Dipole Density Capabilities to Objectively Visualize the Etiology of Rhythms in Atrial Fibrillation) was conducted at 13 centers across Europe and Canada. Patients with persistent AF (>7 days, <1 year) aged 18 to 80 years, scheduled for de novo catheter ablation, were eligible. Before pulmonary vein isolation, AF was mapped and then iteratively remapped to guide each subsequent ablation of charge density-identified targets. AF recurrence was evaluated at 3, 6, 9, and 12 months using continuous 24-hour ECG monitors. The primary effectiveness outcome was freedom from AF >30 seconds at 12 months for a single procedure with a secondary outcome being acute procedural efficacy. The primary safety outcome was freedom from device/procedure-related major adverse events. Results Between October 2016 and April 2017, 129 patients were enrolled, and 127 underwent mapping and catheter ablation. Acute procedural efficacy was demonstrated in 125 patients (98%). At 12 months, single procedure freedom from AF on or off antiarrhythmic drugs was 72.5% (95% CI, 63.9%-80.3%). After 1 or 2 procedures, freedom from AF was 93.2% (95% CI, 87.1%-97.0%). A total of 29 (23%) retreatments because of arrhythmia recurrence were performed with average time from index procedure to first retreatment being 7 months. The primary safety outcome was 98% with no device-related major adverse events reported. Conclusions This novel ultrasound imaging and charge density mapping system safely guided ablation of nonpulmonary vein targets in persistent AF patients with 73% single procedure and 93% second procedure freedom from AF at 12 months.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000476908000008
EID výsledku v databázi Scopus
2-s2.0-85068915173