Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery Short-Term Outcomes From a Multicenter First-in-Human Study (RADIANCE)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F19%3A00008545" target="_blank" >RIV/00023884:_____/19:00008545 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pubmed/31826648" target="_blank" >https://www.ncbi.nlm.nih.gov/pubmed/31826648</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.119.007541" target="_blank" >10.1161/CIRCEP.119.007541</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery Short-Term Outcomes From a Multicenter First-in-Human Study (RADIANCE)
Popis výsledku v původním jazyce
Background: Balloon catheters facilitate pulmonary vein (PV) isolation, but current technology is limited by either a single ablative element, potentially leading to over-ablation of thin and under-ablation of thick tissue, or prolonged procedure times. Visualized by electroanatomical mapping, a novel compliant radiofrequency balloon catheter with 10 irrigated, flexible electrodes can simultaneously and independently deliver energy. Herein, we evaluated the feasibility, safety, and short-term efficacy of this radiofrequency balloon in a multicenter, single-arm, first-in-human study. Methods: Paroxysmal atrial fibrillation patients underwent PV isolation with the radiofrequency balloon delivered over-the-wire with a deflectable 13.5F sheath. Radiofrequency energy is delivered simultaneously from all electrodes-up to 30 s posteriorly and 60 s anteriorly. Esophageal temperature was monitored in all patients; the esophagus was also mechanically deviated in 10 patients. Results: At 4 sites, 39 patients were treated by 9 operators. The radiofrequency balloon isolated all targeted PVs (152/152), 79.6% with a single application. Electrical reconnection occurred in only 7/150 PVs (4.7%) on adenosine/isoproterenol challenge. Mean procedure, balloon dwell, and fluoroscopy times were 101.6, 40.5, and 17.4 min, respectively. Esophagogastroduodenoscopy revealed asymptomatic esophageal erythema in 5 patients. Phrenic nerve palsy occurred in a patient in whom phrenic pacing was inadvertently omitted. At 3 months, imaging revealed no PV stenosis, and early atrial arrhythmia recurrence occurred in only 10/39 (25.6%) patients. Conclusions: The compliant radiofrequency balloon can directionally tailor energy delivery for efficient, effective, and reasonably safe acute PV isolation.
Název v anglickém jazyce
Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery Short-Term Outcomes From a Multicenter First-in-Human Study (RADIANCE)
Popis výsledku anglicky
Background: Balloon catheters facilitate pulmonary vein (PV) isolation, but current technology is limited by either a single ablative element, potentially leading to over-ablation of thin and under-ablation of thick tissue, or prolonged procedure times. Visualized by electroanatomical mapping, a novel compliant radiofrequency balloon catheter with 10 irrigated, flexible electrodes can simultaneously and independently deliver energy. Herein, we evaluated the feasibility, safety, and short-term efficacy of this radiofrequency balloon in a multicenter, single-arm, first-in-human study. Methods: Paroxysmal atrial fibrillation patients underwent PV isolation with the radiofrequency balloon delivered over-the-wire with a deflectable 13.5F sheath. Radiofrequency energy is delivered simultaneously from all electrodes-up to 30 s posteriorly and 60 s anteriorly. Esophageal temperature was monitored in all patients; the esophagus was also mechanically deviated in 10 patients. Results: At 4 sites, 39 patients were treated by 9 operators. The radiofrequency balloon isolated all targeted PVs (152/152), 79.6% with a single application. Electrical reconnection occurred in only 7/150 PVs (4.7%) on adenosine/isoproterenol challenge. Mean procedure, balloon dwell, and fluoroscopy times were 101.6, 40.5, and 17.4 min, respectively. Esophagogastroduodenoscopy revealed asymptomatic esophageal erythema in 5 patients. Phrenic nerve palsy occurred in a patient in whom phrenic pacing was inadvertently omitted. At 3 months, imaging revealed no PV stenosis, and early atrial arrhythmia recurrence occurred in only 10/39 (25.6%) patients. Conclusions: The compliant radiofrequency balloon can directionally tailor energy delivery for efficient, effective, and reasonably safe acute PV isolation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000503199500004
EID výsledku v databázi Scopus
2-s2.0-85076469068