Optimisation of abdominal CT exam protocols in obese patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F22%3A00009261" target="_blank" >RIV/00023884:_____/22:00009261 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article/198/9-11/560/6672971?login=true" target="_blank" >https://academic.oup.com/rpd/article/198/9-11/560/6672971?login=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac099" target="_blank" >10.1093/rpd/ncac099</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimisation of abdominal CT exam protocols in obese patients
Popis výsledku v původním jazyce
Obesity is marked as a global epidemic, and the number of obese people is steadily increasing. This disease affects various aspects of health care, which also includes radiodiagnostic imaging modalities. CT exams of bariatric patients are becoming common in radiological practice and bring problems of both technical and physical nature. Obesity affects the quality of CT images, therefore, optimisation of the used CT protocols is important, which is difficult to be carried out on patients, because of the principles of radiation protection and ethical point of view. This study evaluates and compares three available CT protocols for examination of the abdomen in terms of image quality, radiation dose and scan time on two CT scanners of the manufacturer Siemens. For optimisation, an anthropomorphic phantom of the abdomen was used, which, by its size and attenuation of the used materials, suitably simulated an obese patient.
Název v anglickém jazyce
Optimisation of abdominal CT exam protocols in obese patients
Popis výsledku anglicky
Obesity is marked as a global epidemic, and the number of obese people is steadily increasing. This disease affects various aspects of health care, which also includes radiodiagnostic imaging modalities. CT exams of bariatric patients are becoming common in radiological practice and bring problems of both technical and physical nature. Obesity affects the quality of CT images, therefore, optimisation of the used CT protocols is important, which is difficult to be carried out on patients, because of the principles of radiation protection and ethical point of view. This study evaluates and compares three available CT protocols for examination of the abdomen in terms of image quality, radiation dose and scan time on two CT scanners of the manufacturer Siemens. For optimisation, an anthropomorphic phantom of the abdomen was used, which, by its size and attenuation of the used materials, suitably simulated an obese patient.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
1742-3406
e-ISSN
—
Svazek periodika
198
Číslo periodika v rámci svazku
9-11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
560-565
Kód UT WoS článku
000844405700012
EID výsledku v databázi Scopus
—