Comparison of two types eye lens dosemeters used in interventional cardiology and radiology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F22%3A00009427" target="_blank" >RIV/00023884:_____/22:00009427 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article-abstract/198/9-11/580/6673016?redirectedFrom=fulltext&login=true" target="_blank" >https://academic.oup.com/rpd/article-abstract/198/9-11/580/6673016?redirectedFrom=fulltext&login=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac101" target="_blank" >10.1093/rpd/ncac101</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of two types eye lens dosemeters used in interventional cardiology and radiology
Popis výsledku v původním jazyce
The aim of this contribution is to provide an overview of comparison of two types of eye lens dosemeter systems. The comparison was performed at the Department of Intravenous Cardiology using patient and physician phantoms and supplemented by dose simulation using the Monte Carlo method. The tests were performed in several specific geometries and in addition to eye lens dosemeters the value of a personal dosemeter located at the reference point was also monitored. The value of H-p(3) and H-p(10) was monitored. It is clear from the results that film dosemeters achieve more correct results in most cases. It is probably due to a better correction for the angle of exposure. This assumption must be verified by more detailed measurements in laboratory conditions.
Název v anglickém jazyce
Comparison of two types eye lens dosemeters used in interventional cardiology and radiology
Popis výsledku anglicky
The aim of this contribution is to provide an overview of comparison of two types of eye lens dosemeter systems. The comparison was performed at the Department of Intravenous Cardiology using patient and physician phantoms and supplemented by dose simulation using the Monte Carlo method. The tests were performed in several specific geometries and in addition to eye lens dosemeters the value of a personal dosemeter located at the reference point was also monitored. The value of H-p(3) and H-p(10) was monitored. It is clear from the results that film dosemeters achieve more correct results in most cases. It is probably due to a better correction for the angle of exposure. This assumption must be verified by more detailed measurements in laboratory conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
1742-3406
e-ISSN
—
Svazek periodika
198
Číslo periodika v rámci svazku
9-11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
580-585
Kód UT WoS článku
000844405700015
EID výsledku v databázi Scopus
2-s2.0-85137124350