Chronic wireless communication between dual-chamber leadless pacemaker devices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010207" target="_blank" >RIV/00023884:_____/25:00010207 - isvavai.cz</a>
Výsledek na webu
<a href="http://linkinghub.elsevier.com/retrieve/pii/S1547-5271(24)03446-5" target="_blank" >http://linkinghub.elsevier.com/retrieve/pii/S1547-5271(24)03446-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.hrthm.2024.10.020" target="_blank" >10.1016/j.hrthm.2024.10.020</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Chronic wireless communication between dual-chamber leadless pacemaker devices
Popis výsledku v původním jazyce
BACKGROUND Aveir DR (Abbott, Abbott Park, IL) is a dual-chamber leadless pacemaker (LP) system with distinct atrial and ventricular LPs (ALP, VLP) that communicate wirelessly to deliver atrioventricular synchronous pacing. Success rates of these implant-to-implant (i2i) transmissions have not been systematically evaluated. OBJECTIVE This study aims to evaluate chronic i2i success rates in a clinical setting. METHODS Patients meeting standard dual-chamber pacing indications were enrolled and implanted with dual-chamber LP systems as part of a prospective international clinical trial (Aveir DR i2i Study). The percent of successful i2i transmissions from ALPto-VLP (A-to-V) and VLP-to-ALP (V-to-A) were interrogated from LPs in de novo patients using the device programmer at implant, discharge, and at 1, 3, and 6 months postimplant (1M, 3M, 6M). RESULTS A total of 399 patients completed device implant and i2i diagnostic interrogation (62% male; age 69 years; 65% sinus node dysfunction, 32% atrioventricular [AV] block). Median A-to-V and V-to-A i2i success rates exceeded 90% of beats at all time-points from implant to 6M. The minority of patients with A-to-V or V-to-A i2i success in <70% of beats at implant (A-to-V: 19% of patients, V-to-A: 31% of patients) showed roughly 40% improvement by 1M, with this minority dropping to roughly 5% of patients by 6M. Improvement in i2i communication success may be attributed to reprogramming of i2i setting levels, natural changes in dominant posture, and device stabilization. CONCLUSION Wireless implant-to-implant communication in the new dual-chamber leadless pacemaker system demonstrated successful transmissions in >90% of beats throughout the 6-month evaluation period. Communication success improved significantly over time postimplant for specific subgroups.
Název v anglickém jazyce
Chronic wireless communication between dual-chamber leadless pacemaker devices
Popis výsledku anglicky
BACKGROUND Aveir DR (Abbott, Abbott Park, IL) is a dual-chamber leadless pacemaker (LP) system with distinct atrial and ventricular LPs (ALP, VLP) that communicate wirelessly to deliver atrioventricular synchronous pacing. Success rates of these implant-to-implant (i2i) transmissions have not been systematically evaluated. OBJECTIVE This study aims to evaluate chronic i2i success rates in a clinical setting. METHODS Patients meeting standard dual-chamber pacing indications were enrolled and implanted with dual-chamber LP systems as part of a prospective international clinical trial (Aveir DR i2i Study). The percent of successful i2i transmissions from ALPto-VLP (A-to-V) and VLP-to-ALP (V-to-A) were interrogated from LPs in de novo patients using the device programmer at implant, discharge, and at 1, 3, and 6 months postimplant (1M, 3M, 6M). RESULTS A total of 399 patients completed device implant and i2i diagnostic interrogation (62% male; age 69 years; 65% sinus node dysfunction, 32% atrioventricular [AV] block). Median A-to-V and V-to-A i2i success rates exceeded 90% of beats at all time-points from implant to 6M. The minority of patients with A-to-V or V-to-A i2i success in <70% of beats at implant (A-to-V: 19% of patients, V-to-A: 31% of patients) showed roughly 40% improvement by 1M, with this minority dropping to roughly 5% of patients by 6M. Improvement in i2i communication success may be attributed to reprogramming of i2i setting levels, natural changes in dominant posture, and device stabilization. CONCLUSION Wireless implant-to-implant communication in the new dual-chamber leadless pacemaker system demonstrated successful transmissions in >90% of beats throughout the 6-month evaluation period. Communication success improved significantly over time postimplant for specific subgroups.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart Rhythm
ISSN
1547-5271
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
1010-1020
Kód UT WoS článku
001460689600001
EID výsledku v databázi Scopus
2-s2.0-85208584608