One-Year Safety and Performance of a Dual-Chamber Leadless Pacemaker
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010209" target="_blank" >RIV/00023884:_____/25:00010209 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.ahajournals.org/doi/10.1161/CIRCEP.124.013619" target="_blank" >https://www.ahajournals.org/doi/10.1161/CIRCEP.124.013619</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.124.013619" target="_blank" >10.1161/CIRCEP.124.013619</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
One-Year Safety and Performance of a Dual-Chamber Leadless Pacemaker
Popis výsledku v původním jazyce
BACKGROUND:A dual-chamber leadless pacemaker can provide bradycardia therapy to most patients with pacemaker indications without the complications associated with a lead or pulse generator. We sought to confirm whether previously reported 3-month safety and performance outcomes were sustained through 12 months by determining whether 12-month complication-free and performance success rates exceeded their prespecified performance goals. METHODS:Patients were enrolled in the prospective, single-group Aveir DR i2i Study if they had a standard indication for dual-chamber pacing. Enrolled patients were implanted with an Aveir DR dual-chamber leadless pacemaker system, which comprised 2 communicating leadless pacemakers (1 in the right atrium and 1 in the right ventricle). The primary safety outcome evaluated whether freedom from serious device- or procedure-related events through 365 days exceeded the predetermined performance goal of 76.5%. The primary performance outcome determined whether the composite of atrial capture threshold (<= 3.0 V at 0.4 ms) and sensing amplitude (P-wave >= 1.0 mV) at the 12-month visit exceeded the predetermined performance goal of 80.0%. RESULTS:Sites attempted implantation in 300 subjects, where 63.3% had sinus-node dysfunction and 33.3% had atrioventricular block as their primary pacing indication. The primary safety end point was achieved, with a Kaplan-Meier 12-month complication-free rate of 88.6% (95% CI, 84.5-91.8; P<0.001). The primary performance end point was achieved in 92.8% of patients (95% CI, 89.7-95.8; P<0.001). CONCLUSIONS:Both primary safety and performance end points were met after 1 year, demonstrating consistency with previously reported 3-month outcomes of a dual-chamber leadless pacemaker.
Název v anglickém jazyce
One-Year Safety and Performance of a Dual-Chamber Leadless Pacemaker
Popis výsledku anglicky
BACKGROUND:A dual-chamber leadless pacemaker can provide bradycardia therapy to most patients with pacemaker indications without the complications associated with a lead or pulse generator. We sought to confirm whether previously reported 3-month safety and performance outcomes were sustained through 12 months by determining whether 12-month complication-free and performance success rates exceeded their prespecified performance goals. METHODS:Patients were enrolled in the prospective, single-group Aveir DR i2i Study if they had a standard indication for dual-chamber pacing. Enrolled patients were implanted with an Aveir DR dual-chamber leadless pacemaker system, which comprised 2 communicating leadless pacemakers (1 in the right atrium and 1 in the right ventricle). The primary safety outcome evaluated whether freedom from serious device- or procedure-related events through 365 days exceeded the predetermined performance goal of 76.5%. The primary performance outcome determined whether the composite of atrial capture threshold (<= 3.0 V at 0.4 ms) and sensing amplitude (P-wave >= 1.0 mV) at the 12-month visit exceeded the predetermined performance goal of 80.0%. RESULTS:Sites attempted implantation in 300 subjects, where 63.3% had sinus-node dysfunction and 33.3% had atrioventricular block as their primary pacing indication. The primary safety end point was achieved, with a Kaplan-Meier 12-month complication-free rate of 88.6% (95% CI, 84.5-91.8; P<0.001). The primary performance end point was achieved in 92.8% of patients (95% CI, 89.7-95.8; P<0.001). CONCLUSIONS:Both primary safety and performance end points were met after 1 year, demonstrating consistency with previously reported 3-month outcomes of a dual-chamber leadless pacemaker.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Svazek periodika
18
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
299-308
Kód UT WoS článku
001468720300008
EID výsledku v databázi Scopus
2-s2.0-105002406187