Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010221" target="_blank" >RIV/00023884:_____/25:00010221 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023001:_____/25:00085825
Výsledek na webu
<a href="https://academic.oup.com/europace/article/27/9/euaf139/8182687" target="_blank" >https://academic.oup.com/europace/article/27/9/euaf139/8182687</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euaf139" target="_blank" >10.1093/europace/euaf139</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)
Popis výsledku v původním jazyce
Aims The feasibility and safety of the lattice-tip catheter for ventricular arrhythmia (VA) ablation in humans remain largely unknown. This study aimed to assess feasibility, safety profile as well as patient outcomes after VA ablation with a lattice-tip catheter in a multicentre European registry.Methods and results All 18 European centres using the AFFERA system in September 2024 agreed to participate. Clinical, procedural, and follow-up data (minimum 3 months) were systematically collected and analysed. A total of 126 patients (18% female; mean age 59 +/- 16 years) underwent VA ablation using the lattice-tip catheter during the inclusion period. Ablation indications included ventricular tachycardia (VT) in 99, premature ventricular complexes (PVCs) in 23, and ventricular fibrillation (VF) in 4 patients. Major and minor acute complications were observed in 7 (6%) and 18 (14%) procedures, respectively. They included thrombo-embolic event (n = 2), major bleeding (n = 2), ventricular fibrillation induction (n = 1), tamponade due to epicardial access (n = 1), and cardiogenic shock due to prolonged VT mapping (n = 1). Within the first month post-procedure, three patients died [from multi-organ failure (n = 2) and sepsis (n = 1)], two had worsening heart failure, one myocardial infarction, one sepsis, and one major gastro-intestinal bleeding. After a mean follow-up of 5.6 +/- 3.7 months, absence of recurrence was 78% for PVC, 70% for VT, and 100% for VF.Conclusion In this complex population with refractory VA, ablation using the lattice-tip catheter appears feasible and relatively safe. In the absence of large, randomized trials, exhaustive registry is of key importance to ensure safety and efficacy of new catheter technologies.
Název v anglickém jazyce
Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)
Popis výsledku anglicky
Aims The feasibility and safety of the lattice-tip catheter for ventricular arrhythmia (VA) ablation in humans remain largely unknown. This study aimed to assess feasibility, safety profile as well as patient outcomes after VA ablation with a lattice-tip catheter in a multicentre European registry.Methods and results All 18 European centres using the AFFERA system in September 2024 agreed to participate. Clinical, procedural, and follow-up data (minimum 3 months) were systematically collected and analysed. A total of 126 patients (18% female; mean age 59 +/- 16 years) underwent VA ablation using the lattice-tip catheter during the inclusion period. Ablation indications included ventricular tachycardia (VT) in 99, premature ventricular complexes (PVCs) in 23, and ventricular fibrillation (VF) in 4 patients. Major and minor acute complications were observed in 7 (6%) and 18 (14%) procedures, respectively. They included thrombo-embolic event (n = 2), major bleeding (n = 2), ventricular fibrillation induction (n = 1), tamponade due to epicardial access (n = 1), and cardiogenic shock due to prolonged VT mapping (n = 1). Within the first month post-procedure, three patients died [from multi-organ failure (n = 2) and sepsis (n = 1)], two had worsening heart failure, one myocardial infarction, one sepsis, and one major gastro-intestinal bleeding. After a mean follow-up of 5.6 +/- 3.7 months, absence of recurrence was 78% for PVC, 70% for VT, and 100% for VF.Conclusion In this complex population with refractory VA, ablation using the lattice-tip catheter appears feasible and relatively safe. In the absence of large, randomized trials, exhaustive registry is of key importance to ensure safety and efficacy of new catheter technologies.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
001566491700001
EID výsledku v databázi Scopus
2-s2.0-105015467758