On the gravimetric contribution to watt balance experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00025615%3A_____%2F13%3A%230001948" target="_blank" >RIV/00025615:_____/13:#0001948 - isvavai.cz</a>
Výsledek na webu
<a href="http://iopscience.iop.org/0026-1394/50/5/452" target="_blank" >http://iopscience.iop.org/0026-1394/50/5/452</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0026-1394/50/5/452" target="_blank" >10.1088/0026-1394/50/5/452</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the gravimetric contribution to watt balance experiments
Popis výsledku v původním jazyce
It has been recommended that the relative standard uncertainty of the numerical value of the Planck constant required for the redefinition of the kilogram should not exceed 2E-8. To reach this goal using experiments based on a watt balance, the free-fallacceleration (g) traceable to the SI, at a given point and a given time, needs to be known with a sufficiently small uncertainty well below 2E-8. Reducing the uncertainty in g allows the other uncertainties related to the watt balance to be increased. Instead of a simultaneous operation of an absolute gravimeter with a watt balance, we propose an alternative approach and demonstrate that a standard uncertainty below 5 microGal (relative uncertainty of 5E-9) is reachable under the conditions at BIPM. Inour approach we combine the following information: (1) the Key Comparison Reference Values obtained from the CCM.G-K1, a key comparison carried out in the frame of the International Comparison of Absolute Gravimeters in 2009 (ICAG2009);
Název v anglickém jazyce
On the gravimetric contribution to watt balance experiments
Popis výsledku anglicky
It has been recommended that the relative standard uncertainty of the numerical value of the Planck constant required for the redefinition of the kilogram should not exceed 2E-8. To reach this goal using experiments based on a watt balance, the free-fallacceleration (g) traceable to the SI, at a given point and a given time, needs to be known with a sufficiently small uncertainty well below 2E-8. Reducing the uncertainty in g allows the other uncertainties related to the watt balance to be increased. Instead of a simultaneous operation of an absolute gravimeter with a watt balance, we propose an alternative approach and demonstrate that a standard uncertainty below 5 microGal (relative uncertainty of 5E-9) is reachable under the conditions at BIPM. Inour approach we combine the following information: (1) the Key Comparison Reference Values obtained from the CCM.G-K1, a key comparison carried out in the frame of the International Comparison of Absolute Gravimeters in 2009 (ICAG2009);
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DE - Zemský magnetismus, geodesie, geografie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0090" target="_blank" >ED1.1.00/02.0090: NTIS - Nové technologie pro informační společnost</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
0026-1394
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
20
Strana od-do
452-471