Matrix effects during laser ablation MC ICP-MS analysis of boron isotopes in tourmaline
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00025798%3A_____%2F14%3A00000113" target="_blank" >RIV/00025798:_____/14:00000113 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.rsc.org/en/Content/ArticleLanding/2014/JA/c3ja50241d#!divAbstract" target="_blank" >http://pubs.rsc.org/en/Content/ArticleLanding/2014/JA/c3ja50241d#!divAbstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c3ja50241d" target="_blank" >10.1039/c3ja50241d</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Matrix effects during laser ablation MC ICP-MS analysis of boron isotopes in tourmaline
Popis výsledku v původním jazyce
Laser ablation multi-collector inductively coupled plasma mass spectrometry (LA MC ICP-MS) and secondary ion mass spectrometry (SIMS) were used to determine the boron isotopic compositions of several natural tourmaline group minerals (elbaite, schorl anddravite). This study reports on the effects of instrument parameters of LA MC ICP-MS and the composition of sample matrix on data accuracy, reproducibility and repeatability. We demonstrate that the tourmaline matrix has a significant effect on the obtained delta B-11 values and impacts on data accuracy, with a bias of up to ca. 2.5 parts per thousand if a non matrix-matched reference material is used to calibrate the measurements. In the case of a matrix-matched calibration, the boron isotopic data obtained by LA MC ICP-MS are comparable to the reference TIMS values, with typical repeatability for delta B-11 results between 0.2 and 0.5 parts per thousand (1s). This is somewhat better compared to the repeatability of 0.8-1.3 parts per
Název v anglickém jazyce
Matrix effects during laser ablation MC ICP-MS analysis of boron isotopes in tourmaline
Popis výsledku anglicky
Laser ablation multi-collector inductively coupled plasma mass spectrometry (LA MC ICP-MS) and secondary ion mass spectrometry (SIMS) were used to determine the boron isotopic compositions of several natural tourmaline group minerals (elbaite, schorl anddravite). This study reports on the effects of instrument parameters of LA MC ICP-MS and the composition of sample matrix on data accuracy, reproducibility and repeatability. We demonstrate that the tourmaline matrix has a significant effect on the obtained delta B-11 values and impacts on data accuracy, with a bias of up to ca. 2.5 parts per thousand if a non matrix-matched reference material is used to calibrate the measurements. In the case of a matrix-matched calibration, the boron isotopic data obtained by LA MC ICP-MS are comparable to the reference TIMS values, with typical repeatability for delta B-11 results between 0.2 and 0.5 parts per thousand (1s). This is somewhat better compared to the repeatability of 0.8-1.3 parts per
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Analytical Atomic Spectrometry
ISSN
0267-9477
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
903-914
Kód UT WoS článku
000334737300014
EID výsledku v databázi Scopus
—