The fate of Cr(VI) in contaminated aquifers 65 years after the first spillage of plating solutions: A δ53Cr study at four Central European sites
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00025798%3A_____%2F17%3A00000181" target="_blank" >RIV/00025798:_____/17:00000181 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0341816217302370" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0341816217302370</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.catena.2017.07.004" target="_blank" >10.1016/j.catena.2017.07.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The fate of Cr(VI) in contaminated aquifers 65 years after the first spillage of plating solutions: A δ53Cr study at four Central European sites
Popis výsledku v původním jazyce
Chromium isotope systematics and concentrations of dissolved Cr were studied in shallow aquifers at four industrial sites in the Czech Republic, Central Europe. Chromium plating baths and wastewaters started to contaminate groundwater in the late 1940s. Since plating shops at all sites still operate, it was possible to determine the δ53Cr signatures of the plating baths. The mean δ53Cr values of the Cr plating baths, representing contamination sources, were 0.0 ‰ at Zlate Hory (ZH), 0.5 ‰ at Loucna nad Desnou (LD), 0.3 ‰ at Letnany (AV), and 0.1 ‰ at Velesin (JI). At all sites, groundwater Cr was isotopically heavier, compared to the contamination source, reflecting natural in-situ Cr(VI) reduction to insoluble Cr(III). The magnitude of the average positive isotope shift from the plating bath Cr(VI) to groundwater Craq, mostly residual Cr(VI), was 1.1 ‰, 1.3 ‰, 3.3 ‰ and 3.3 ‰ at ZH, LD, AV, and JI, respectively. The mean concentration of Craq was 0.43, 0.47, 2.38 and 4.32 mg L-1, respectively. AV and JI, the sites with lower residual Craq concentrations in groundwater, had higher δ53Cr values, suggesting higher rates/efficiency of Cr(VI) reduction, and of toxicity removal. Simple Rayleigh models indicated that as much as 60 % of Cr(VI) has been removed from the groundwater by spontaneous reduction at AV and JI. At ZH and LD, the same models indicated a 30 % Cr removal from the solution. Even if uncertainties in model application and Cr fractionation factors are considered, it appears that natural attenuation at Cr(VI)-polluted sites can improve groundwater quality by tens of percent in a relatively short period of time of several decades.
Název v anglickém jazyce
The fate of Cr(VI) in contaminated aquifers 65 years after the first spillage of plating solutions: A δ53Cr study at four Central European sites
Popis výsledku anglicky
Chromium isotope systematics and concentrations of dissolved Cr were studied in shallow aquifers at four industrial sites in the Czech Republic, Central Europe. Chromium plating baths and wastewaters started to contaminate groundwater in the late 1940s. Since plating shops at all sites still operate, it was possible to determine the δ53Cr signatures of the plating baths. The mean δ53Cr values of the Cr plating baths, representing contamination sources, were 0.0 ‰ at Zlate Hory (ZH), 0.5 ‰ at Loucna nad Desnou (LD), 0.3 ‰ at Letnany (AV), and 0.1 ‰ at Velesin (JI). At all sites, groundwater Cr was isotopically heavier, compared to the contamination source, reflecting natural in-situ Cr(VI) reduction to insoluble Cr(III). The magnitude of the average positive isotope shift from the plating bath Cr(VI) to groundwater Craq, mostly residual Cr(VI), was 1.1 ‰, 1.3 ‰, 3.3 ‰ and 3.3 ‰ at ZH, LD, AV, and JI, respectively. The mean concentration of Craq was 0.43, 0.47, 2.38 and 4.32 mg L-1, respectively. AV and JI, the sites with lower residual Craq concentrations in groundwater, had higher δ53Cr values, suggesting higher rates/efficiency of Cr(VI) reduction, and of toxicity removal. Simple Rayleigh models indicated that as much as 60 % of Cr(VI) has been removed from the groundwater by spontaneous reduction at AV and JI. At ZH and LD, the same models indicated a 30 % Cr removal from the solution. Even if uncertainties in model application and Cr fractionation factors are considered, it appears that natural attenuation at Cr(VI)-polluted sites can improve groundwater quality by tens of percent in a relatively short period of time of several decades.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10618 - Ecology
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-21373S" target="_blank" >GA15-21373S: Izotopová hmotová bilance lokalit znečištěných chrómem podle poměru četnosti 53Cr/52Cr pevných a kapalných vzorků</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Catena
ISSN
0341-8162
e-ISSN
—
Svazek periodika
158
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
371-380
Kód UT WoS článku
000412252200034
EID výsledku v databázi Scopus
2-s2.0-85026389493