Some causes of differences in the NH3 concentration measured with the semiconductor sensors by one manufacturer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00027031%3A_____%2F16%3AN0000080" target="_blank" >RIV/00027031:_____/16:N0000080 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41340/16:73021
Výsledek na webu
<a href="http://www.vuzt.cz/svt/vuzt/publ/P2016/096.pdf" target="_blank" >http://www.vuzt.cz/svt/vuzt/publ/P2016/096.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17221/80/2015-RAE" target="_blank" >10.17221/80/2015-RAE</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Some causes of differences in the NH3 concentration measured with the semiconductor sensors by one manufacturer
Popis výsledku v původním jazyce
The paper deals with continuous monitoring of NH3 desorption from material used as bedding in animal breeding establishments, using five semiconductor sensors SP-53 (FIS Inc.). In lab experiments, two groups of sensors from two categories, to which the manufacturer divided the sensors based on the value of their resistance RS, were used. Also the influence of air humidity over the values of NH3 concentrations measured by individual sensors was monitored. The study ascertained statistically relevant differences between NH3 concentration values measured by both groups of sensors, in the range from 8.5% to 23.1%. The biggest differences were confirmed for relative air humidity around 85%. It was verified that setting a convenient value of the load resistance RL with regard to the RS of each sensor, along with the selection of limited range of measured temperatures and relative air humidity, leads to satisfactory correction of the sensor output data, regardless of the division of sensors in categories pursuant to the value of their resistance in manufacturing.
Název v anglickém jazyce
Some causes of differences in the NH3 concentration measured with the semiconductor sensors by one manufacturer
Popis výsledku anglicky
The paper deals with continuous monitoring of NH3 desorption from material used as bedding in animal breeding establishments, using five semiconductor sensors SP-53 (FIS Inc.). In lab experiments, two groups of sensors from two categories, to which the manufacturer divided the sensors based on the value of their resistance RS, were used. Also the influence of air humidity over the values of NH3 concentrations measured by individual sensors was monitored. The study ascertained statistically relevant differences between NH3 concentration values measured by both groups of sensors, in the range from 8.5% to 23.1%. The biggest differences were confirmed for relative air humidity around 85%. It was verified that setting a convenient value of the load resistance RL with regard to the RS of each sensor, along with the selection of limited range of measured temperatures and relative air humidity, leads to satisfactory correction of the sensor output data, regardless of the division of sensors in categories pursuant to the value of their resistance in manufacturing.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/QJ1210375" target="_blank" >QJ1210375: Výzkum systému chovu dojnic z hlediska optimalizace mikroklimatu a energeticko-ekonomické náročnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Research in Agricultural Engineering
ISSN
1212-9151
e-ISSN
—
Svazek periodika
62
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
190–197
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85009230819