Modified needle route for potential reduction of the trans-obturator inside-out-related thigh pain: a cadaveric study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F11%3A9975" target="_blank" >RIV/00064165:_____/11:9975 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10397-010-0635-7" target="_blank" >http://dx.doi.org/10.1007/s10397-010-0635-7</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modified needle route for potential reduction of the trans-obturator inside-out-related thigh pain: a cadaveric study
Popis výsledku v původním jazyce
To evaluate the anatomical aspects and relations of a modified tissue passage with the tension-free vaginal tape obturator (TVT-O) needle, designed for the purpose of reduction of the thigh pain, related with this anti-urinary incontinence operation. Thedistances between the modified TVT-O surgically inserted needle and obturator nerve branches were measured in fresh cadaver. The introduced surgical needle caused no trauma to any of the adjacent cadaveric organs, and the distances between the surgicalneedle and the obturator nerve branches was 4 cm. The modified TVT-O needle route is shown to be safe and remote from the obturator nerve branches, thus conduction of a clinical study for evaluation of related pain reduction is recommended. 2010 Springer-Verlag.
Název v anglickém jazyce
Modified needle route for potential reduction of the trans-obturator inside-out-related thigh pain: a cadaveric study
Popis výsledku anglicky
To evaluate the anatomical aspects and relations of a modified tissue passage with the tension-free vaginal tape obturator (TVT-O) needle, designed for the purpose of reduction of the thigh pain, related with this anti-urinary incontinence operation. Thedistances between the modified TVT-O surgically inserted needle and obturator nerve branches were measured in fresh cadaver. The introduced surgical needle caused no trauma to any of the adjacent cadaveric organs, and the distances between the surgicalneedle and the obturator nerve branches was 4 cm. The modified TVT-O needle route is shown to be safe and remote from the obturator nerve branches, thus conduction of a clinical study for evaluation of related pain reduction is recommended. 2010 Springer-Verlag.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FK - Gynekologie a porodnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Gynecological Surgery
ISSN
1613-2076
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
4
Strana od-do
171-174
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—