Echocardiography and cardiac resynchronization therapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F16%3A10328350" target="_blank" >RIV/00064165:_____/16:10328350 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/16:10328350
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.crvasa.2015.08.001" target="_blank" >http://dx.doi.org/10.1016/j.crvasa.2015.08.001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2015.08.001" target="_blank" >10.1016/j.crvasa.2015.08.001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Echocardiography and cardiac resynchronization therapy
Popis výsledku v původním jazyce
Cardiac resynchronization therapy (CRT) is an effective therapeutic option in patients with congestive heart failure, left ventricular ejection fraction LESS-THAN OR EQUAL TO 35%, and a widened QRS complex. However, a significant proportion of individuals do not respond to CRT favorably. Understandably, a large number of studies have addressed various techniques to improve patient selection for CRT and to improve responder rate in patients with CRT devices. A large proportion of these approaches utilize echocardiography. Techniques for improved patient selection include various metrics of dyssynchrony that could be associated with response to CRT and long-term outcome. Partly because of failure in the PROSPECT trial, these techniques have not been successfully translated into clinical practice thus far.
Název v anglickém jazyce
Echocardiography and cardiac resynchronization therapy
Popis výsledku anglicky
Cardiac resynchronization therapy (CRT) is an effective therapeutic option in patients with congestive heart failure, left ventricular ejection fraction LESS-THAN OR EQUAL TO 35%, and a widened QRS complex. However, a significant proportion of individuals do not respond to CRT favorably. Understandably, a large number of studies have addressed various techniques to improve patient selection for CRT and to improve responder rate in patients with CRT devices. A large proportion of these approaches utilize echocardiography. Techniques for improved patient selection include various metrics of dyssynchrony that could be associated with response to CRT and long-term outcome. Partly because of failure in the PROSPECT trial, these techniques have not been successfully translated into clinical practice thus far.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
"e340"-"e351"
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84941584772