Effect of sterilization on mechanical properties of collagen-based composite tubes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F17%3A10375603" target="_blank" >RIV/00064165:_____/17:10375603 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/17:00316654
Výsledek na webu
<a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4303/4157" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4303/4157</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of sterilization on mechanical properties of collagen-based composite tubes
Popis výsledku v původním jazyce
In this study, composite tubes were manufactured from biological collagenous matrix and reinforcing polyester mesh. The effect of sterilization on mechanical properties of this structure was evaluated using inflation-extension tests. Samples were exposed to two types of sterilization (ethylene oxide and gamma irradiation). The control (non-sterilized) samples were also tested. The closed thick walled tube model was used in order to compute stresses within sterilized and control specimens. It was found that the process of sterilization (especially irradiation) dramatically affects the final mechanical properties of the material. These findings should be taken into account when such collagenous material is assumed to be used in tissue engineering.
Název v anglickém jazyce
Effect of sterilization on mechanical properties of collagen-based composite tubes
Popis výsledku anglicky
In this study, composite tubes were manufactured from biological collagenous matrix and reinforcing polyester mesh. The effect of sterilization on mechanical properties of this structure was evaluated using inflation-extension tests. Samples were exposed to two types of sterilization (ethylene oxide and gamma irradiation). The control (non-sterilized) samples were also tested. The closed thick walled tube model was used in order to compute stresses within sterilized and control specimens. It was found that the process of sterilization (especially irradiation) dramatically affects the final mechanical properties of the material. These findings should be taken into account when such collagenous material is assumed to be used in tissue engineering.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV15-27941A" target="_blank" >NV15-27941A: Využití neantigenního rybího kolagenu při konstrukci implantátů a jako nosiče léků</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lékař a technika
ISSN
0301-5491
e-ISSN
—
Svazek periodika
47
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
15-18
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85026286452