Wave Kurtosis: A Novel, Specific Parameter for TUG-Turn Quantification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10384221" target="_blank" >RIV/00064165:_____/19:10384221 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/19:10384221
Výsledek na webu
<a href="https://doi.org/10.1007/978-981-10-9038-7_64" target="_blank" >https://doi.org/10.1007/978-981-10-9038-7_64</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-981-10-9038-7_64" target="_blank" >10.1007/978-981-10-9038-7_64</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wave Kurtosis: A Novel, Specific Parameter for TUG-Turn Quantification
Popis výsledku v původním jazyce
The Timed Up and Go test (TUG) is widely used in both research and clinical settings. The most common parameter for quantification of functional decline is the duration of a performed TUG. Analysis of the turn part of the TUG could provide valuable information about functional decline. Notwithstanding, there are only a few studies that deals with the TUG turn processing. This study proposes a novelty parameter-wave kurtosis (WK) that provides quantitative metrics for describing and comparing turn patterns. The WK is designed to evaluate the shape of the signal waveform. The WK quantifies the peak of the signal, its position and tails. The TUG-turn angular rate was analysed. Intra-class correlations (ICC) of WK and the strength of a linear association between WK and established turn parameters (turn duration, peak angular rate, and mean angular rate) were calculated. The reliability of WK about the vertical axis was moderate (ICC > 0.50), while reliabilities of the frontal axis and sagittal axis varied according to the subject group. The WK about the vertical axis was moderately correlated with turn duration, mean value and peak value. Utilization of waveform parameters opens a new area of TUG turn analysis and may allow for a more sensitive determination of movement disorders or fall risk assessment. Therefore, future studies utilizing turn movement may benefit from the use of the wave kurtosis.
Název v anglickém jazyce
Wave Kurtosis: A Novel, Specific Parameter for TUG-Turn Quantification
Popis výsledku anglicky
The Timed Up and Go test (TUG) is widely used in both research and clinical settings. The most common parameter for quantification of functional decline is the duration of a performed TUG. Analysis of the turn part of the TUG could provide valuable information about functional decline. Notwithstanding, there are only a few studies that deals with the TUG turn processing. This study proposes a novelty parameter-wave kurtosis (WK) that provides quantitative metrics for describing and comparing turn patterns. The WK is designed to evaluate the shape of the signal waveform. The WK quantifies the peak of the signal, its position and tails. The TUG-turn angular rate was analysed. Intra-class correlations (ICC) of WK and the strength of a linear association between WK and established turn parameters (turn duration, peak angular rate, and mean angular rate) were calculated. The reliability of WK about the vertical axis was moderate (ICC > 0.50), while reliabilities of the frontal axis and sagittal axis varied according to the subject group. The WK about the vertical axis was moderately correlated with turn duration, mean value and peak value. Utilization of waveform parameters opens a new area of TUG turn analysis and may allow for a more sensitive determination of movement disorders or fall risk assessment. Therefore, future studies utilizing turn movement may benefit from the use of the wave kurtosis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Congress on Medical Physics and Biomedical Engineering 2018
ISBN
978-981-10-9037-0
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
5
Strana od-do
339-343
Název nakladatele
Springer
Místo vydání
Singapore
Místo konání akce
Prague
Datum konání akce
3. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000449742700064