Validity of six consumer-level activity monitors for measuring steps in patients with chronic heart failure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10399323" target="_blank" >RIV/00064165:_____/19:10399323 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/19:10399323 RIV/00216208:11130/19:10399323 RIV/00216208:11510/19:10399323
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Gik6zi6KHZ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Gik6zi6KHZ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0222569" target="_blank" >10.1371/journal.pone.0222569</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Validity of six consumer-level activity monitors for measuring steps in patients with chronic heart failure
Popis výsledku v původním jazyce
Introduction Although numerous activity trackers have been validated in healthy populations, validation is lacking in chronic heart failure patients who normally walk at a slower pace, making it difficult for researchers and clinicians to implement activity monitors during physical activity interventions. Methods Six consumer-level activity monitors were validated in a 3-day field study in patients with chronic heart failure and healthy individuals under free living conditions. Furthermore, the same devices were evaluated in a lab-based study during treadmill walking at speeds of 2.4, 3.0, 3.6, and 4.2 km.h-1. Concordance correlation coefficients (CCC) were used to evaluate the agreement between the activity monitors and the criterion, and mean absolute percentage errors (MAPE) were calculated to assess differences between each device and the criterion (MAPE <10% was considered as a threshold for validity). Results In the field study of healthy individuals, all but one of the activity monitors showed a substantial correlation (CCC .0.95) with the criterion device and MAPE <10%. In patients with heart failure, the correlation of only two activity monitors (Garmin vívofit 3 and Withings Go) was classified as at least moderate (CCC >=0.90) and none of the devices had MAPE <10%. In the lab-based study at speeds 4.2 and 3.6 km.h-1, all activity monitors showed substantial to almost perfect correlations (CCC >=0.95) with the criterion and MAPE in the range 1%-3%. However, at slower speeds of 3.0 and 2.4 km.h-1, the accuracy of all devices substantially deteriorated: their correlation with the criterion decreased below 90% and their MAPE increased to 4-8% and 10-45%, respectively. Conclusions Even though none of the tested activity monitors fall within arbitrary thresholds for validity, most of them perform reasonably well enough to be useful tools that clinicians can use to simply motivate chronic heart failure patients to walk more. (C) 2019 Vetrovsky et al.
Název v anglickém jazyce
Validity of six consumer-level activity monitors for measuring steps in patients with chronic heart failure
Popis výsledku anglicky
Introduction Although numerous activity trackers have been validated in healthy populations, validation is lacking in chronic heart failure patients who normally walk at a slower pace, making it difficult for researchers and clinicians to implement activity monitors during physical activity interventions. Methods Six consumer-level activity monitors were validated in a 3-day field study in patients with chronic heart failure and healthy individuals under free living conditions. Furthermore, the same devices were evaluated in a lab-based study during treadmill walking at speeds of 2.4, 3.0, 3.6, and 4.2 km.h-1. Concordance correlation coefficients (CCC) were used to evaluate the agreement between the activity monitors and the criterion, and mean absolute percentage errors (MAPE) were calculated to assess differences between each device and the criterion (MAPE <10% was considered as a threshold for validity). Results In the field study of healthy individuals, all but one of the activity monitors showed a substantial correlation (CCC .0.95) with the criterion device and MAPE <10%. In patients with heart failure, the correlation of only two activity monitors (Garmin vívofit 3 and Withings Go) was classified as at least moderate (CCC >=0.90) and none of the devices had MAPE <10%. In the lab-based study at speeds 4.2 and 3.6 km.h-1, all activity monitors showed substantial to almost perfect correlations (CCC >=0.95) with the criterion and MAPE in the range 1%-3%. However, at slower speeds of 3.0 and 2.4 km.h-1, the accuracy of all devices substantially deteriorated: their correlation with the criterion decreased below 90% and their MAPE increased to 4-8% and 10-45%, respectively. Conclusions Even though none of the tested activity monitors fall within arbitrary thresholds for validity, most of them perform reasonably well enough to be useful tools that clinicians can use to simply motivate chronic heart failure patients to walk more. (C) 2019 Vetrovsky et al.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/NV18-09-00146" target="_blank" >NV18-09-00146: Účinnost chodecké intervence s využitím krokoměru na fyzickou zdatnost a neurohumorální modulaci u pacientů s chronickým srdečním selháním</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PLoS One
ISSN
1932-6203
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
1-14
Kód UT WoS článku
000499486400001
EID výsledku v databázi Scopus
2-s2.0-85072184309