How to recognize stent graft infection after endovascular aortic repair: the utility of 18F-FDG PET/CT in an infrequent but serious clinical setting
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10400045" target="_blank" >RIV/00064165:_____/19:10400045 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/19:10400045
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=v.PZJvo_Xc" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=v.PZJvo_Xc</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s12149-019-01370-9" target="_blank" >10.1007/s12149-019-01370-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
How to recognize stent graft infection after endovascular aortic repair: the utility of 18F-FDG PET/CT in an infrequent but serious clinical setting
Popis výsledku v původním jazyce
Objective: To evaluate the diagnostic performance of 18F-FDG PET/CT in the detection of stent graft infection (SGI). Methods: In a retrospective study, two nuclear medicine physicians have independently analyzed 17 18F-FDG PET/CT examinations performed for clinical suspicion of SGI. The images were evaluated for the uptake pattern and intensity, and by the maximum standard uptake value (SUVmax), the target-to-background ratio with blood pool (TBRBP) and liver uptake (TBRhep) as a reference. The SGI was defined as the presence of focal hyperactivity with an intensity exceeding hepatic uptake. CT images were independently assessed for signs of SGI. Clinical review of all further patients' data served as the standard of reference. Results: Nine cases were established as SGI by the clinical review. PET/CT correctly diagnosed SGI in eight and yielded a sensitivity of 89% and specificity of 100%. The mean SUVmax, TBRBP, and TBRhep values were 9.8 +- 4.0, 6.9 +- 2.6, and 4.6 +- 1.7 in the group of patients with true SGI, and 4.0 +- 1.1, 2.5 +- 0.4 (p < 0.001) and 1.9 +- 0.2 (p < 0.001) in true negative cases, respectively. CT alone showed a sensitivity of 78% and specificity of 100% and was concordant with PET/CT in 14 cases. The best performing threshold values of SUVmax, TBRBP, and TBRhep were 5.6, 3.5, and 2.2, respectively. Conclusion: 18F-FDG PET/CT with expert evaluation, semiquantitative and quantitative image analysis with the proposed threshold values for SUVmax, TBRBP, and TBRhep has good diagnostic accuracy in the detection of SGI. We propose that visual grading scale for SGI should use hepatic uptake as a visual reference.
Název v anglickém jazyce
How to recognize stent graft infection after endovascular aortic repair: the utility of 18F-FDG PET/CT in an infrequent but serious clinical setting
Popis výsledku anglicky
Objective: To evaluate the diagnostic performance of 18F-FDG PET/CT in the detection of stent graft infection (SGI). Methods: In a retrospective study, two nuclear medicine physicians have independently analyzed 17 18F-FDG PET/CT examinations performed for clinical suspicion of SGI. The images were evaluated for the uptake pattern and intensity, and by the maximum standard uptake value (SUVmax), the target-to-background ratio with blood pool (TBRBP) and liver uptake (TBRhep) as a reference. The SGI was defined as the presence of focal hyperactivity with an intensity exceeding hepatic uptake. CT images were independently assessed for signs of SGI. Clinical review of all further patients' data served as the standard of reference. Results: Nine cases were established as SGI by the clinical review. PET/CT correctly diagnosed SGI in eight and yielded a sensitivity of 89% and specificity of 100%. The mean SUVmax, TBRBP, and TBRhep values were 9.8 +- 4.0, 6.9 +- 2.6, and 4.6 +- 1.7 in the group of patients with true SGI, and 4.0 +- 1.1, 2.5 +- 0.4 (p < 0.001) and 1.9 +- 0.2 (p < 0.001) in true negative cases, respectively. CT alone showed a sensitivity of 78% and specificity of 100% and was concordant with PET/CT in 14 cases. The best performing threshold values of SUVmax, TBRBP, and TBRhep were 5.6, 3.5, and 2.2, respectively. Conclusion: 18F-FDG PET/CT with expert evaluation, semiquantitative and quantitative image analysis with the proposed threshold values for SUVmax, TBRBP, and TBRhep has good diagnostic accuracy in the detection of SGI. We propose that visual grading scale for SGI should use hepatic uptake as a visual reference.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of Nuclear Medicine
ISSN
0914-7187
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
JP - Japonsko
Počet stran výsledku
12
Strana od-do
594-605
Kód UT WoS článku
000477648000007
EID výsledku v databázi Scopus
2-s2.0-85066631421