Normative reference ranges for echocardiographic chamber dimensions in a healthy Central European population: results from the Czech post-MONICA survey
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10401973" target="_blank" >RIV/00064165:_____/19:10401973 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/19:10401973 RIV/00064190:_____/19:N0000013
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=3tXMGv1jgj" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=3tXMGv1jgj</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12947-019-0172-0" target="_blank" >10.1186/s12947-019-0172-0</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Normative reference ranges for echocardiographic chamber dimensions in a healthy Central European population: results from the Czech post-MONICA survey
Popis výsledku v původním jazyce
Background: Normative reference values for echocardiographic chamber quantification are of great importance; however, this can be challenging. Our aim was to derive these values including degrees of abnormality from a random Central European population sample with a homogeneous subset of healthy subjects. Methods: We analysed echocardiograms obtained in a randomly selected population sample during the Czech post-MONICA survey in 2007/2008. Overall, 1850 out of 2273 persons of the whole sample of three districts had adequate echocardiograms (81.4%). A healthy subgroup defined by the absence of known cardiovascular disease was used to define normal reference range limits (n = 575, median age 42 years [IQR 34-52], 57% females). The whole population sample with predefined percentile cut-offs was used to define degrees of abnormality. Results: Left ventricular (LV) size tended to decrease with age, while LV mass increased with age in both males and females and in both the healthy and general populations. LV dimensions were larger in males, except for body surface area-indexed LV diameter. M-mode derived LV measurements were larger and LV mass higher compared to 2D measurements. Right ventricle basal dimension was larger in males. Conclusions: Our study provides reference ranges for echocardiographic measurements obtained in a healthy subgroup derived from an epidemiological study of a Central European population. Where feasible, degrees of abnormality are provided based on the whole population sample including patients with disease. Our data show that age, gender and measurement method significantly affect cardiac dimensions and function and should be always taken into account.
Název v anglickém jazyce
Normative reference ranges for echocardiographic chamber dimensions in a healthy Central European population: results from the Czech post-MONICA survey
Popis výsledku anglicky
Background: Normative reference values for echocardiographic chamber quantification are of great importance; however, this can be challenging. Our aim was to derive these values including degrees of abnormality from a random Central European population sample with a homogeneous subset of healthy subjects. Methods: We analysed echocardiograms obtained in a randomly selected population sample during the Czech post-MONICA survey in 2007/2008. Overall, 1850 out of 2273 persons of the whole sample of three districts had adequate echocardiograms (81.4%). A healthy subgroup defined by the absence of known cardiovascular disease was used to define normal reference range limits (n = 575, median age 42 years [IQR 34-52], 57% females). The whole population sample with predefined percentile cut-offs was used to define degrees of abnormality. Results: Left ventricular (LV) size tended to decrease with age, while LV mass increased with age in both males and females and in both the healthy and general populations. LV dimensions were larger in males, except for body surface area-indexed LV diameter. M-mode derived LV measurements were larger and LV mass higher compared to 2D measurements. Right ventricle basal dimension was larger in males. Conclusions: Our study provides reference ranges for echocardiographic measurements obtained in a healthy subgroup derived from an epidemiological study of a Central European population. Where feasible, degrees of abnormality are provided based on the whole population sample including patients with disease. Our data show that age, gender and measurement method significantly affect cardiac dimensions and function and should be always taken into account.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV15-27109A" target="_blank" >NV15-27109A: Dlouhodobé trendy hlavních kardiovaskulárních rizikových faktorů a jejich prediktivní hodnota v náhodně vybraném populačním vzorku, Czech post-MONICA</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cardiovascular Ultrasound [online]
ISSN
1476-7120
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
22
Kód UT WoS článku
000502841300001
EID výsledku v databázi Scopus
2-s2.0-85074324385