Smear layer deproteinization with NaOCl and HOCl: Do application/wash-out times affect dentin bonding of one-step self-etch adhesives?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F22%3A10434950" target="_blank" >RIV/00064165:_____/22:10434950 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/22:10434950
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=TX5luPni.m" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=TX5luPni.m</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4012/dmj.2021-208" target="_blank" >10.4012/dmj.2021-208</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Smear layer deproteinization with NaOCl and HOCl: Do application/wash-out times affect dentin bonding of one-step self-etch adhesives?
Popis výsledku v původním jazyce
This study investigated the influence of application/wash-out times of sodium hypochlorite (NaOCl) and hypochlorous acid (HOCl) on dentin bond strength of one-step self-etch adhesives (1-SEAs). Human coronal dentin discs with a standardized smear layer were pretreated with 6% NaOCl or 100 ppm HOCl for 5s, 15s, or 30s, and washed out with water for 5s, 15s or 30s with or without the application of Clearfil DC Activator (CDA). No pretreatment was used as a control. The discs were bonded with a 1-SEA (Bond Force II or Clearfil Universal Bond Quick) and microtensile bond strength (µTBS) was measured after 24h. Pretreatment with NaOCl for 15s and 30s significantly decreased µTBS (p<0.05), irrespective of wash-out time. The application of CDA recovered µTBS but did not outperform the control group. Conversely, pretreatment with HOCl for 15s and 30s followed by 30s wash-out time significantly increased µTBS of 1-SEAs (p<0.05), regardless of CDA application.
Název v anglickém jazyce
Smear layer deproteinization with NaOCl and HOCl: Do application/wash-out times affect dentin bonding of one-step self-etch adhesives?
Popis výsledku anglicky
This study investigated the influence of application/wash-out times of sodium hypochlorite (NaOCl) and hypochlorous acid (HOCl) on dentin bond strength of one-step self-etch adhesives (1-SEAs). Human coronal dentin discs with a standardized smear layer were pretreated with 6% NaOCl or 100 ppm HOCl for 5s, 15s, or 30s, and washed out with water for 5s, 15s or 30s with or without the application of Clearfil DC Activator (CDA). No pretreatment was used as a control. The discs were bonded with a 1-SEA (Bond Force II or Clearfil Universal Bond Quick) and microtensile bond strength (µTBS) was measured after 24h. Pretreatment with NaOCl for 15s and 30s significantly decreased µTBS (p<0.05), irrespective of wash-out time. The application of CDA recovered µTBS but did not outperform the control group. Conversely, pretreatment with HOCl for 15s and 30s followed by 30s wash-out time significantly increased µTBS of 1-SEAs (p<0.05), regardless of CDA application.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Dental Materials Journal
ISSN
0287-4547
e-ISSN
—
Svazek periodika
41
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
JP - Japonsko
Počet stran výsledku
10
Strana od-do
353-362
Kód UT WoS článku
000918791200003
EID výsledku v databázi Scopus
2-s2.0-85131268546