Preoperative staging of ovarian cancer: comparison between ultrasound, CT and whole-body diffusion-weighted MRI (ISAAC study)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F22%3A10439513" target="_blank" >RIV/00064165:_____/22:10439513 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/22:10439513 RIV/00064211:_____/22:W0000020
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oCzotyB-QR" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oCzotyB-QR</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/uog.23654" target="_blank" >10.1002/uog.23654</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Preoperative staging of ovarian cancer: comparison between ultrasound, CT and whole-body diffusion-weighted MRI (ISAAC study)
Popis výsledku v původním jazyce
Objectives: To compare the performance of transvaginal and transabdominal ultrasound with that of the first-line staging method (contrast-enhanced computed tomography (CT)) and a novel technique, whole-body magnetic resonance imaging with diffusion-weighted sequence (WB-DWI/MRI), in the assessment of peritoneal involvement (carcinomatosis), lymph-node staging and prediction of non-resectability in patients with suspected ovarian cancer. Methods: Between March 2016 and October 2017, all consecutive patients with suspicion of ovarian cancer and surgery planned at a gynecological oncology center underwent preoperative staging and prediction of non-resectability with ultrasound, CT and WB-DWI/MRI. The evaluation followed a single, predefined protocol, assessing peritoneal spread at 19 sites and lymph-node metastasis at eight sites. The prediction of non-resectability was based on abdominal markers. Findings were compared to the reference standard (surgical findings and outcome and histopathological evaluation). Results: Sixty-seven patients with confirmed ovarian cancer were analyzed. Among them, 51 (76%) had advanced-stage and 16 (24%) had early-stage ovarian cancer. Diagnostic laparoscopy only was performed in 16% (11/67) of the cases and laparotomy in 84% (56/67), with no residual disease at the end of surgery in 68% (38/56), residual disease <= 1 cm in 16% (9/56) and residual disease > 1 cm in 16% (9/56). Ultrasound and WB-DWI/MRI performed better than did CT in the assessment of overall peritoneal carcinomatosis (area under the receiver-operating-characteristics curve (AUC), 0.87, 0.86 and 0.77, respectively). Ultrasound was not inferior to CT (P = 0.002). For assessment of retroperitoneal lymph-node staging (AUC, 0.72-0.76) and prediction of non-resectability in the abdomen (AUC, 0.74-0.80), all three methods performed similarly. In general, ultrasound had higher or identical specificity to WB-DWI/MRI and CT at each of the 19 peritoneal sites evaluated, but lower or equal sensitivity in the abdomen. Compared with WB-DWI/MRI and CT, transvaginal ultrasound had higher accuracy (94% vs 91% and 85%, respectively) and sensitivity (94% vs 91% and 89%, respectively) in the detection of carcinomatosis in the pelvis. Better accuracy and sensitivity of ultrasound (93% and 100%) than WB-DWI/MRI (83% and 75%) and CT (84% and 88%) in the evaluation of deep rectosigmoid wall infiltration, in particular, supports the potential role of ultrasound in planning rectosigmoid resection. In contrast, for the bowel serosal and mesenterial assessment, abdominal ultrasound had the lowest accuracy (70%, 78% and 79%, respectively) and sensitivity (42%, 65% and 65%, respectively). Conclusions: This is the first prospective study to document that, in experienced hands, ultrasound may be an alternative to WB-DWI/MRI and CT in ovarian cancer staging, including peritoneal and lymph-node evaluation and prediction of non-resectability based on abdominal markers of non-resectability. (C) 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Název v anglickém jazyce
Preoperative staging of ovarian cancer: comparison between ultrasound, CT and whole-body diffusion-weighted MRI (ISAAC study)
Popis výsledku anglicky
Objectives: To compare the performance of transvaginal and transabdominal ultrasound with that of the first-line staging method (contrast-enhanced computed tomography (CT)) and a novel technique, whole-body magnetic resonance imaging with diffusion-weighted sequence (WB-DWI/MRI), in the assessment of peritoneal involvement (carcinomatosis), lymph-node staging and prediction of non-resectability in patients with suspected ovarian cancer. Methods: Between March 2016 and October 2017, all consecutive patients with suspicion of ovarian cancer and surgery planned at a gynecological oncology center underwent preoperative staging and prediction of non-resectability with ultrasound, CT and WB-DWI/MRI. The evaluation followed a single, predefined protocol, assessing peritoneal spread at 19 sites and lymph-node metastasis at eight sites. The prediction of non-resectability was based on abdominal markers. Findings were compared to the reference standard (surgical findings and outcome and histopathological evaluation). Results: Sixty-seven patients with confirmed ovarian cancer were analyzed. Among them, 51 (76%) had advanced-stage and 16 (24%) had early-stage ovarian cancer. Diagnostic laparoscopy only was performed in 16% (11/67) of the cases and laparotomy in 84% (56/67), with no residual disease at the end of surgery in 68% (38/56), residual disease <= 1 cm in 16% (9/56) and residual disease > 1 cm in 16% (9/56). Ultrasound and WB-DWI/MRI performed better than did CT in the assessment of overall peritoneal carcinomatosis (area under the receiver-operating-characteristics curve (AUC), 0.87, 0.86 and 0.77, respectively). Ultrasound was not inferior to CT (P = 0.002). For assessment of retroperitoneal lymph-node staging (AUC, 0.72-0.76) and prediction of non-resectability in the abdomen (AUC, 0.74-0.80), all three methods performed similarly. In general, ultrasound had higher or identical specificity to WB-DWI/MRI and CT at each of the 19 peritoneal sites evaluated, but lower or equal sensitivity in the abdomen. Compared with WB-DWI/MRI and CT, transvaginal ultrasound had higher accuracy (94% vs 91% and 85%, respectively) and sensitivity (94% vs 91% and 89%, respectively) in the detection of carcinomatosis in the pelvis. Better accuracy and sensitivity of ultrasound (93% and 100%) than WB-DWI/MRI (83% and 75%) and CT (84% and 88%) in the evaluation of deep rectosigmoid wall infiltration, in particular, supports the potential role of ultrasound in planning rectosigmoid resection. In contrast, for the bowel serosal and mesenterial assessment, abdominal ultrasound had the lowest accuracy (70%, 78% and 79%, respectively) and sensitivity (42%, 65% and 65%, respectively). Conclusions: This is the first prospective study to document that, in experienced hands, ultrasound may be an alternative to WB-DWI/MRI and CT in ovarian cancer staging, including peritoneal and lymph-node evaluation and prediction of non-resectability based on abdominal markers of non-resectability. (C) 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/NV19-03-00552" target="_blank" >NV19-03-00552: Zobrazovací studie u pokročilého nádoru vaječníků (ISAAC studie, lmaging Study on Advanced ovArian Cancer)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ultrasound in Obstetrics and Gynecology
ISSN
0960-7692
e-ISSN
1469-0705
Svazek periodika
59
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
15
Strana od-do
248-262
Kód UT WoS článku
000749268300016
EID výsledku v databázi Scopus
2-s2.0-85123969556