Polymerization shrinkage of light-cured conventional and bulk-fill composites - the effect of cavity depth and post-curing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F23%3A10451544" target="_blank" >RIV/00064165:_____/23:10451544 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/23:10451544
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vjPhc5qvM_" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vjPhc5qvM_</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4012/dmj.2022-210" target="_blank" >10.4012/dmj.2022-210</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Polymerization shrinkage of light-cured conventional and bulk-fill composites - the effect of cavity depth and post-curing
Popis výsledku v původním jazyce
Volumetric shrinkage (VS) of conventional, bulk-fill, and core build-up resin-based composites (RBCs) of various thickness (1-5mm) was measured using the modified bonded-disk method with confocal laser scanning microscopy. Additionally, the bottom-to-top ratio of Vickers hardness (%VH) was measured. Conventional RBCs exhibited significantly higher VS than bulk-fill and core build-up RBCs (p<0.05). As specimen thickness increased, VS relative to volume (%VS) and difference in VS at each depth (VSdepth) decreased. For conventional RBCs, there was a significant drop in VSdepth between 1mm and 2mm (p<0.05), and another drop was observed between 3mm and 4mm (p<0.05) where %VH decreased below 90%. For bulk-fill and core build-up RBCs, VSdepth decreased significantly between 2mm and 3mm (p<0.05), but %VH exceeded 90% even in 5mm deep cavities. These results indicated that post-curing contributed to lower shrinkage in deeper layers, and that conventional RBCs were not adequately polymerized at the depth of over 3mm.
Název v anglickém jazyce
Polymerization shrinkage of light-cured conventional and bulk-fill composites - the effect of cavity depth and post-curing
Popis výsledku anglicky
Volumetric shrinkage (VS) of conventional, bulk-fill, and core build-up resin-based composites (RBCs) of various thickness (1-5mm) was measured using the modified bonded-disk method with confocal laser scanning microscopy. Additionally, the bottom-to-top ratio of Vickers hardness (%VH) was measured. Conventional RBCs exhibited significantly higher VS than bulk-fill and core build-up RBCs (p<0.05). As specimen thickness increased, VS relative to volume (%VS) and difference in VS at each depth (VSdepth) decreased. For conventional RBCs, there was a significant drop in VSdepth between 1mm and 2mm (p<0.05), and another drop was observed between 3mm and 4mm (p<0.05) where %VH decreased below 90%. For bulk-fill and core build-up RBCs, VSdepth decreased significantly between 2mm and 3mm (p<0.05), but %VH exceeded 90% even in 5mm deep cavities. These results indicated that post-curing contributed to lower shrinkage in deeper layers, and that conventional RBCs were not adequately polymerized at the depth of over 3mm.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Dental Materials Journal
ISSN
0287-4547
e-ISSN
1881-1361
Svazek periodika
42
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
JP - Japonsko
Počet stran výsledku
7
Strana od-do
426-432
Kód UT WoS článku
001081896700016
EID výsledku v databázi Scopus
2-s2.0-85160966535