Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F24%3A10475184" target="_blank" >RIV/00064165:_____/24:10475184 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/24:10475184 RIV/00216208:11130/24:10475184 RIV/00064203:_____/24:10475184
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0-.mTVxy2r" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0-.mTVxy2r</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.fas.2024.01.005" target="_blank" >10.1016/j.fas.2024.01.005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation
Popis výsledku v původním jazyce
BACKGROUND: Injections around the Achilles tendon (AT) are commonly performed in clinical practice to manage non-insertional Achilles tendinopathy, but the presence/distribution of the injectate with relation to its sheath has not been assessed specifically. Accordingly, the aim of this cadaveric investigation was to demonstrate the feasibility of Achilles paratenon injection under ultrasound guidance - by confirming the exact needle positioning as well as the dye distribution inside the paratenon lumen. METHODS: A descriptive laboratory study with three human cadaveric specimens (one fresh cadaver and two cadavers embalmed using the Fix for Life (F4L) method) was performed in a tertiary-care academic institution. The interventional technique and the related anatomical findings were illustrated. During the injection, the needle was advanced inside the Achilles paratenon under ultrasound guidance i.e. in-plane medial-to-lateral approach. With the objective to confirm its correct placement, the needle was kept in situ on the right AT of the fresh cadaver. Likewise, to demonstrate the location of the dye inside the lumen of Achilles paratenon, the other five ATs - four on the embalmed cadavers and one on the fresh cadaver - were injected with 5 mL of green color dye. After removal of the needle, a layer-by-layer anatomical dissection was performed on all three cadavers. RESULTS: On the right AT of the fresh cadaver, the position of the needle's tip within the Achilles paratenon was confirmed. Accurate placement of the dye inside the paratenon lumen was confirmed in four (80%) ATs, one of the fresh and three of the embalmed cadavers. No spread inside the crural fascia compartment or between the AT and the Kager's fat pad was observed. Herewith, unintentional spilling of the dye within the superficial soft tissues of the posterior leg was reported in the left AT of one of the two embalmed cadavers (20%). CONCLUSIONS: Ultrasound-guided injection using the in-plane, medial-to-lateral approach can accurately target the lumen of Achilles paratenon.
Název v anglickém jazyce
Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation
Popis výsledku anglicky
BACKGROUND: Injections around the Achilles tendon (AT) are commonly performed in clinical practice to manage non-insertional Achilles tendinopathy, but the presence/distribution of the injectate with relation to its sheath has not been assessed specifically. Accordingly, the aim of this cadaveric investigation was to demonstrate the feasibility of Achilles paratenon injection under ultrasound guidance - by confirming the exact needle positioning as well as the dye distribution inside the paratenon lumen. METHODS: A descriptive laboratory study with three human cadaveric specimens (one fresh cadaver and two cadavers embalmed using the Fix for Life (F4L) method) was performed in a tertiary-care academic institution. The interventional technique and the related anatomical findings were illustrated. During the injection, the needle was advanced inside the Achilles paratenon under ultrasound guidance i.e. in-plane medial-to-lateral approach. With the objective to confirm its correct placement, the needle was kept in situ on the right AT of the fresh cadaver. Likewise, to demonstrate the location of the dye inside the lumen of Achilles paratenon, the other five ATs - four on the embalmed cadavers and one on the fresh cadaver - were injected with 5 mL of green color dye. After removal of the needle, a layer-by-layer anatomical dissection was performed on all three cadavers. RESULTS: On the right AT of the fresh cadaver, the position of the needle's tip within the Achilles paratenon was confirmed. Accurate placement of the dye inside the paratenon lumen was confirmed in four (80%) ATs, one of the fresh and three of the embalmed cadavers. No spread inside the crural fascia compartment or between the AT and the Kager's fat pad was observed. Herewith, unintentional spilling of the dye within the superficial soft tissues of the posterior leg was reported in the left AT of one of the two embalmed cadavers (20%). CONCLUSIONS: Ultrasound-guided injection using the in-plane, medial-to-lateral approach can accurately target the lumen of Achilles paratenon.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30106 - Anatomy and morphology (plant science to be 1.6)
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Foot and Ankle Surgery
ISSN
1268-7731
e-ISSN
1460-9584
Svazek periodika
30
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
313-318
Kód UT WoS článku
001294475900001
EID výsledku v databázi Scopus
2-s2.0-85184064578