Semi-automated RNA Isolation from Tempus Blood RNA Tubes Using the Magcore Plus II Instrument
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F25%3A10499691" target="_blank" >RIV/00064165:_____/25:10499691 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/25:10499691 RIV/00216208:11310/25:10499691
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=t-.9wU.kBZ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=t-.9wU.kBZ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14712/fb2025071020088" target="_blank" >10.14712/fb2025071020088</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Semi-automated RNA Isolation from Tempus Blood RNA Tubes Using the Magcore Plus II Instrument
Popis výsledku v původním jazyce
High-throughput, precise and cost-effective isolation of high-quality RNA is essential for the growing number of RNA-based next-generation sequencing (NGS) analyses. Manual RNA isolation provides sufficient quality but requires significant hands-on time and carries an increased risk of contamination and sample misidentification. Here we describe a semi-automated protocol for the isolation of high-quality total RNA from 3 ml of peripheral blood collected in Tempus Blood RNA Tubes. The isolation can be performed either from the total volume of 9 ml of Tempus blood lysate or from smaller volumes (6 and 3 ml, respectively) using the MagCore triXact RNA Kit on the MagCore Plus II automated nucleic acid extractor, which allows RNA isolation in single tubes. The original isolation protocol (#631) for whole blood RNA isolation was customized by the manufacturer (#631T) by omitting the cell lysis step. After optimizing the process, we compared the yield and quality of 760 RNA samples isolated manually or by semi-automated methods. We conclude that RNA isolation using the semi-automated MagCore protocol yields 5-10 μg of total RNA from 6 ml of lysate (2 ml of peripheral blood), which is almost comparable in quantity and quality to manual isolation. In addition, we show that the remaining 3 ml of lysate is sufficient for backup re-isolation. Our semi-automated RNA protocol reduces hands-on time without increasing costs and yields bulky total RNA of a quali-ty suitable for subsequent RNA NGS applications.
Název v anglickém jazyce
Semi-automated RNA Isolation from Tempus Blood RNA Tubes Using the Magcore Plus II Instrument
Popis výsledku anglicky
High-throughput, precise and cost-effective isolation of high-quality RNA is essential for the growing number of RNA-based next-generation sequencing (NGS) analyses. Manual RNA isolation provides sufficient quality but requires significant hands-on time and carries an increased risk of contamination and sample misidentification. Here we describe a semi-automated protocol for the isolation of high-quality total RNA from 3 ml of peripheral blood collected in Tempus Blood RNA Tubes. The isolation can be performed either from the total volume of 9 ml of Tempus blood lysate or from smaller volumes (6 and 3 ml, respectively) using the MagCore triXact RNA Kit on the MagCore Plus II automated nucleic acid extractor, which allows RNA isolation in single tubes. The original isolation protocol (#631) for whole blood RNA isolation was customized by the manufacturer (#631T) by omitting the cell lysis step. After optimizing the process, we compared the yield and quality of 760 RNA samples isolated manually or by semi-automated methods. We conclude that RNA isolation using the semi-automated MagCore protocol yields 5-10 μg of total RNA from 6 ml of lysate (2 ml of peripheral blood), which is almost comparable in quantity and quality to manual isolation. In addition, we show that the remaining 3 ml of lysate is sufficient for backup re-isolation. Our semi-automated RNA protocol reduces hands-on time without increasing costs and yields bulky total RNA of a quali-ty suitable for subsequent RNA NGS applications.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30100 - Basic medicine
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Folia Biologica
ISSN
0015-5500
e-ISSN
2533-7602
Svazek periodika
71
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
88-94
Kód UT WoS článku
001529657600005
EID výsledku v databázi Scopus
2-s2.0-105010975104