Reinforced aneurysmorrhaphy for true aneurysmal haemodialysis vascular access
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F14%3AN0000035" target="_blank" >RIV/00064173:_____/14:N0000035 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064190:_____/14:#0000748 RIV/00159816:_____/14:00060947 RIV/00216208:11110/14:10290831 RIV/00216208:11120/14:43908425 a 2 dalších
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ejvs.2014.01.010" target="_blank" >http://dx.doi.org/10.1016/j.ejvs.2014.01.010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ejvs.2014.01.010" target="_blank" >10.1016/j.ejvs.2014.01.010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reinforced aneurysmorrhaphy for true aneurysmal haemodialysis vascular access
Popis výsledku v původním jazyce
Objective: In 2008, a new technique of reinforced aneurysmorrhaphy with a polyester mesh tube for salvaging true aneurysmal arteriovenous (AV) haemodialysis access was described by us. In this study, the long-term patency and complication rates associated with this procedure were analysed, and the effect of reinforced aneurysmorrhaphy on high-flow vascular access was assessed. Methods: This was a retrospective non-randomised study with prospectively collected data performed at a single centre. Patients with true aneurysmal haemodialysis AV access who underwent aneurysmorrhaphy with external mesh prosthesis between March 2007 and October 2012 were included. Clinical assessment and duplex ultrasound were performed preoperatively, 1, 3, and 12 months postoperatively, and annually thereafter. Results: Data from 62 patients (median age 60 years, range 28-81 years; 63% men) were analysed. The commonest indication was high-flow vascular access associated with the risk of high output cardiac failure (24 patients, 39%). The mean follow-up time was 14.66 +/- 12.80 months. Primary patency rates at 6 and 12 months were 86% and 79% respectively. Assisted primary patency rates at 6 and 12 months were 89% and 80% respectively. In 23 patients (96%) operated on for high-flow vascular access, decreased vascular access flow was observed after the procedure. The average flow reduction after aneurysmorrhaphy was 2,197 mL/minute. Postoperative bleeding and infection necessitating surgical revision occurred in three (4.8%) and three (4.8%) patients respectively. Conclusions: Reinforced aneurysmorrhaphy with an external mesh prosthesis is an effective method for treating true aneurysmal haemodialysis AV access, with excellent long-term patency and minimal complications due to infection.
Název v anglickém jazyce
Reinforced aneurysmorrhaphy for true aneurysmal haemodialysis vascular access
Popis výsledku anglicky
Objective: In 2008, a new technique of reinforced aneurysmorrhaphy with a polyester mesh tube for salvaging true aneurysmal arteriovenous (AV) haemodialysis access was described by us. In this study, the long-term patency and complication rates associated with this procedure were analysed, and the effect of reinforced aneurysmorrhaphy on high-flow vascular access was assessed. Methods: This was a retrospective non-randomised study with prospectively collected data performed at a single centre. Patients with true aneurysmal haemodialysis AV access who underwent aneurysmorrhaphy with external mesh prosthesis between March 2007 and October 2012 were included. Clinical assessment and duplex ultrasound were performed preoperatively, 1, 3, and 12 months postoperatively, and annually thereafter. Results: Data from 62 patients (median age 60 years, range 28-81 years; 63% men) were analysed. The commonest indication was high-flow vascular access associated with the risk of high output cardiac failure (24 patients, 39%). The mean follow-up time was 14.66 +/- 12.80 months. Primary patency rates at 6 and 12 months were 86% and 79% respectively. Assisted primary patency rates at 6 and 12 months were 89% and 80% respectively. In 23 patients (96%) operated on for high-flow vascular access, decreased vascular access flow was observed after the procedure. The average flow reduction after aneurysmorrhaphy was 2,197 mL/minute. Postoperative bleeding and infection necessitating surgical revision occurred in three (4.8%) and three (4.8%) patients respectively. Conclusions: Reinforced aneurysmorrhaphy with an external mesh prosthesis is an effective method for treating true aneurysmal haemodialysis AV access, with excellent long-term patency and minimal complications due to infection.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: Fakultní nemocnice u sv. Anny v Brně - Mezinárodní centrum klinického výzkumu (FNUSA - ICRC)</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Vascular & Endovascular Surgery
ISSN
1078-5884
e-ISSN
1532-2165
Svazek periodika
47
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
444-450
Kód UT WoS článku
000333855900018
EID výsledku v databázi Scopus
2-s2.0-84896093670