Cardiac Computed Tomography, Transesophageal and Intracardiac Echocardiography, and Fluoroscopy for Planning Left Atrial Appendage Closure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F21%3AN0000097" target="_blank" >RIV/00064173:_____/21:N0000097 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.4022/jafib.20200449" target="_blank" >https://doi.org/10.4022/jafib.20200449</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4022/jafib.20200449" target="_blank" >10.4022/jafib.20200449</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cardiac Computed Tomography, Transesophageal and Intracardiac Echocardiography, and Fluoroscopy for Planning Left Atrial Appendage Closure
Popis výsledku v původním jazyce
Background: Left atrial appendage (LAA) closure (LAAC) is accompanied by a high risk of complications. Due to the complex anatomy of the LAA and the oval-shaped ostium, the proper sizing of the device is often difficult. Purpose: To assess individualized fluoroscopy viewing angles using pre-procedural CT analysis and to compare the results of landing zone measurements obtained from CT, transesophageal echocardiography (TEE), intracardiac echocardiography (ICE), and fluoroscopy. Methods: Patients with indications for LAAC were enrolled. Cardiac CT and TEE were done before the procedure; ICE and fluoroscopy measurements were done peri-procedurally. Multiplanar reconstruction of CT images, using FluoroCT software, was done, and optimal "personalized" viewing angles for fluoroscopy were determined. Moreover, a mean (using multiplanar CT reconstruction, derived from the LAA perimetr) amd maximum (using all four imaging modalitities) landing zone (LZ) of the LAA were masured. Results: Twenty-five patients were analyzed. Despite significant correlation between LZs obtained from different imaging modalities, the values of LZs differed significantly; the mean LZ diameter on CT was 20.60 +- 3.42 mm, the maximum diameters were 21.99 +- 4.03 mm (CT), 18.72 +- 2.44 mm (TEE), 18.20 +- 2.68 mm (ICE), and 17.76 +- 3.24 mm (fluoroscopy). The mean CT diameter matched with the final device selection in 92% patients, while fluoroscopy or TEE maximum diameters in only 72% patients. Optimal viewing angles differed significantly from the fluoroscopy projections usually recommended by the manufacturer in 3 patients. Conclusions: CT provides the best measurement of the LZ and the best prediction of the optimum fluoroscopy projections for the implantation procedure.
Název v anglickém jazyce
Cardiac Computed Tomography, Transesophageal and Intracardiac Echocardiography, and Fluoroscopy for Planning Left Atrial Appendage Closure
Popis výsledku anglicky
Background: Left atrial appendage (LAA) closure (LAAC) is accompanied by a high risk of complications. Due to the complex anatomy of the LAA and the oval-shaped ostium, the proper sizing of the device is often difficult. Purpose: To assess individualized fluoroscopy viewing angles using pre-procedural CT analysis and to compare the results of landing zone measurements obtained from CT, transesophageal echocardiography (TEE), intracardiac echocardiography (ICE), and fluoroscopy. Methods: Patients with indications for LAAC were enrolled. Cardiac CT and TEE were done before the procedure; ICE and fluoroscopy measurements were done peri-procedurally. Multiplanar reconstruction of CT images, using FluoroCT software, was done, and optimal "personalized" viewing angles for fluoroscopy were determined. Moreover, a mean (using multiplanar CT reconstruction, derived from the LAA perimetr) amd maximum (using all four imaging modalitities) landing zone (LZ) of the LAA were masured. Results: Twenty-five patients were analyzed. Despite significant correlation between LZs obtained from different imaging modalities, the values of LZs differed significantly; the mean LZ diameter on CT was 20.60 +- 3.42 mm, the maximum diameters were 21.99 +- 4.03 mm (CT), 18.72 +- 2.44 mm (TEE), 18.20 +- 2.68 mm (ICE), and 17.76 +- 3.24 mm (fluoroscopy). The mean CT diameter matched with the final device selection in 92% patients, while fluoroscopy or TEE maximum diameters in only 72% patients. Optimal viewing angles differed significantly from the fluoroscopy projections usually recommended by the manufacturer in 3 patients. Conclusions: CT provides the best measurement of the LZ and the best prediction of the optimum fluoroscopy projections for the implantation procedure.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Atrial Fibrillation
ISSN
1941-6911
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
26-32
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85119659906