Risk Comparison Using Autologous Dermal Flap and Absorbable Breast Mesh on Patient Undergoing Subcutaneous Mastectomy with Immediate Breast Reconstruction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F22%3A43923012" target="_blank" >RIV/00064173:_____/22:43923012 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/22:43923012
Výsledek na webu
<a href="https://doi.org/10.1007/s00266-022-02799-6" target="_blank" >https://doi.org/10.1007/s00266-022-02799-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00266-022-02799-6" target="_blank" >10.1007/s00266-022-02799-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Risk Comparison Using Autologous Dermal Flap and Absorbable Breast Mesh on Patient Undergoing Subcutaneous Mastectomy with Immediate Breast Reconstruction
Popis výsledku v původním jazyce
In patients with large breasts undergoing a subcutaneous mastectomy with immediate implant-based reconstruction, is necessary to perform a mastopexy. The combination of these procedures increases the complication rate. To reduce it, it is necessary to cover the lower pole of the implant. Our study aimed to compare the use of an autologous dermal flap and an absorbable breast mesh. A total of 64 patients without previous breast surgery were divided into 2 groups, each with 32 patients. In the 1st group, the implant was covered with an autologous caudally based dermal flap, sutured to the great pectoral muscle. In the 2nd group, the implant was covered with a fully absorbable breast mesh, fixed caudally in the inframammary fold and cranially to the great pectoral muscle. The incidence of complications, the aesthetic effect, and patient satisfaction were evaluated in a one-year follow-up. In the 1st group, there were 2 cases of seroma, 2 partial nipple-areola complex necrosis, 4 cases of dehiscence in the T-suture, and the malposition of the implant in 2 patients. In the 2nd group, there were 2 cases of seroma, 2 cases of T-junction dehiscence, and 1 case of full nipple-areola complex necrosis, which resulted in implant loss. There was no significant difference in patient satisfaction between the study groups. The dermal flap is more suitable for breasts with pronounced ptosis. The use of the synthetic mesh is suitable for smaller breasts, where the possible dermal flap would be too small to cover the implant. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Název v anglickém jazyce
Risk Comparison Using Autologous Dermal Flap and Absorbable Breast Mesh on Patient Undergoing Subcutaneous Mastectomy with Immediate Breast Reconstruction
Popis výsledku anglicky
In patients with large breasts undergoing a subcutaneous mastectomy with immediate implant-based reconstruction, is necessary to perform a mastopexy. The combination of these procedures increases the complication rate. To reduce it, it is necessary to cover the lower pole of the implant. Our study aimed to compare the use of an autologous dermal flap and an absorbable breast mesh. A total of 64 patients without previous breast surgery were divided into 2 groups, each with 32 patients. In the 1st group, the implant was covered with an autologous caudally based dermal flap, sutured to the great pectoral muscle. In the 2nd group, the implant was covered with a fully absorbable breast mesh, fixed caudally in the inframammary fold and cranially to the great pectoral muscle. The incidence of complications, the aesthetic effect, and patient satisfaction were evaluated in a one-year follow-up. In the 1st group, there were 2 cases of seroma, 2 partial nipple-areola complex necrosis, 4 cases of dehiscence in the T-suture, and the malposition of the implant in 2 patients. In the 2nd group, there were 2 cases of seroma, 2 cases of T-junction dehiscence, and 1 case of full nipple-areola complex necrosis, which resulted in implant loss. There was no significant difference in patient satisfaction between the study groups. The dermal flap is more suitable for breasts with pronounced ptosis. The use of the synthetic mesh is suitable for smaller breasts, where the possible dermal flap would be too small to cover the implant. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Aesthetic Plastic Surgery
ISSN
0364-216X
e-ISSN
1432-5241
Svazek periodika
46
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
1145-1152
Kód UT WoS článku
000755102700002
EID výsledku v databázi Scopus
2-s2.0-85124721559