Comparison of narrow-band imaging with autofluorescence imaging for endoscopic detection of squamous cell carcinoma of the tonsil
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F23%3A43925905" target="_blank" >RIV/00064173:_____/23:43925905 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/23:10465885 RIV/00216208:11120/23:43925905 RIV/00064203:_____/23:10465885
Výsledek na webu
<a href="https://doi.org/10.1007/s00405-023-08111-9" target="_blank" >https://doi.org/10.1007/s00405-023-08111-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00405-023-08111-9" target="_blank" >10.1007/s00405-023-08111-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of narrow-band imaging with autofluorescence imaging for endoscopic detection of squamous cell carcinoma of the tonsil
Popis výsledku v původním jazyce
PURPOSE: Early detection of mucosal neoplastic lesions is crucial for a patient's prognosis. This has led to the development of effective optical endoscopic diagnostic methods such as narrow band imaging (NBI) and autofluorescence (AFI). Independent of each other, both of these methods were proven useful in the detection of mucosal neoplasias. There are limited reported data comparing both methods for oropharyngeal cancer diagnostics. The aim of the study was to compare NBI and AFI endoscopic visualization of signs in identifying tonsillar squamous cell carcinoma (SCC) and assessing its extent and to determine whether the score was related to the evaluator's experience. METHODS: Patients with tonsillar SCC underwent endoscopic pharyngeal examination using NBI and AFI. Fiftyseven video sequences of examinations of lesions proven to be SCC were evaluated by three reviewers. The accuracy of determination of lesion extent and visualization of its endoscopic signs of malignancy were evaluated. RESULTS: Endoscopic visualization of tumour spread was significantly better using AFI than NBI (p = 0.0003). No significant difference was found between NBI and AFI in the visualization of endoscopic malignancy determining signs (p = 0.1405). No significant difference was found among the three reviewers in the visualization of tumour spread and for identifying malignancy-determining signs in NBI endoscopy or AFI endoscopy. CONCLUSIONS: The results show that AFI obtained better results for assessing the extent of tonsillar cancers than NBI. Both methods were proven to be equal in the visualization of endoscopic malignancy-determining signs. Both are useful even for less experienced evaluators.
Název v anglickém jazyce
Comparison of narrow-band imaging with autofluorescence imaging for endoscopic detection of squamous cell carcinoma of the tonsil
Popis výsledku anglicky
PURPOSE: Early detection of mucosal neoplastic lesions is crucial for a patient's prognosis. This has led to the development of effective optical endoscopic diagnostic methods such as narrow band imaging (NBI) and autofluorescence (AFI). Independent of each other, both of these methods were proven useful in the detection of mucosal neoplasias. There are limited reported data comparing both methods for oropharyngeal cancer diagnostics. The aim of the study was to compare NBI and AFI endoscopic visualization of signs in identifying tonsillar squamous cell carcinoma (SCC) and assessing its extent and to determine whether the score was related to the evaluator's experience. METHODS: Patients with tonsillar SCC underwent endoscopic pharyngeal examination using NBI and AFI. Fiftyseven video sequences of examinations of lesions proven to be SCC were evaluated by three reviewers. The accuracy of determination of lesion extent and visualization of its endoscopic signs of malignancy were evaluated. RESULTS: Endoscopic visualization of tumour spread was significantly better using AFI than NBI (p = 0.0003). No significant difference was found between NBI and AFI in the visualization of endoscopic malignancy determining signs (p = 0.1405). No significant difference was found among the three reviewers in the visualization of tumour spread and for identifying malignancy-determining signs in NBI endoscopy or AFI endoscopy. CONCLUSIONS: The results show that AFI obtained better results for assessing the extent of tonsillar cancers than NBI. Both methods were proven to be equal in the visualization of endoscopic malignancy-determining signs. Both are useful even for less experienced evaluators.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Archives of Oto-Rhino-Laryngology
ISSN
0937-4477
e-ISSN
1434-4726
Svazek periodika
280
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
5073-5080
Kód UT WoS článku
001031426200002
EID výsledku v databázi Scopus
2-s2.0-85165123069