Distribution of mechanical properties of native human ligamentum flavum depending on histopathological changes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F24%3A43927529" target="_blank" >RIV/00064173:_____/24:43927529 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/24:43927529 RIV/68407700:21220/24:00376809
Výsledek na webu
<a href="https://doi.org/10.1088/2057-1976/ad78e2" target="_blank" >https://doi.org/10.1088/2057-1976/ad78e2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/2057-1976/ad78e2" target="_blank" >10.1088/2057-1976/ad78e2</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Distribution of mechanical properties of native human ligamentum flavum depending on histopathological changes
Popis výsledku v původním jazyce
This study aimed to characterize the mechanical properties of native human ligamentum flavum (LF) and correlate them with histopathological changes. Mechanical property gradients across the cranial, medial, and caudal regions of LF were mapped and compared with histological sections. We also compared lumbar spinal stenosis (LSS) samples with disc herniation (DH) samples as reference material to identify differences in mechanical properties and histopathological features. Our results revealed significant heterogeneity in LF mechanical properties, with local variations correlating with specific histopathological changes such as chondroid metaplasia and loss of elastic fibers. These findings underscore the importance of considering LF heterogeneity in mechanical characterization and provide insights into its behavior under pathological conditions.
Název v anglickém jazyce
Distribution of mechanical properties of native human ligamentum flavum depending on histopathological changes
Popis výsledku anglicky
This study aimed to characterize the mechanical properties of native human ligamentum flavum (LF) and correlate them with histopathological changes. Mechanical property gradients across the cranial, medial, and caudal regions of LF were mapped and compared with histological sections. We also compared lumbar spinal stenosis (LSS) samples with disc herniation (DH) samples as reference material to identify differences in mechanical properties and histopathological features. Our results revealed significant heterogeneity in LF mechanical properties, with local variations correlating with specific histopathological changes such as chondroid metaplasia and loss of elastic fibers. These findings underscore the importance of considering LF heterogeneity in mechanical characterization and provide insights into its behavior under pathological conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
<a href="/cs/project/NU21-06-00356" target="_blank" >NU21-06-00356: Změny vaskularizace, fyzikálních a histopatobiochemických vlastností ligamentum flavum bederní páteře v závislosti na úrovni páteřního segmentu a topické lokalizaci a na přítomnosti lumbální spinální stenózy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Physics & Engineering Express
ISSN
2057-1976
e-ISSN
2057-1976
Svazek periodika
10
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
065025
Kód UT WoS článku
001316201200001