Spectral fluence of neutrons generated by radiotherapeutic linacs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064190%3A_____%2F15%3A%230001126" target="_blank" >RIV/00064190:_____/15:#0001126 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00177016:_____/15:#0000859
Výsledek na webu
<a href="http://dx.doi.org/10.1093/rpd/ncu192" target="_blank" >http://dx.doi.org/10.1093/rpd/ncu192</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncu192" target="_blank" >10.1093/rpd/ncu192</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spectral fluence of neutrons generated by radiotherapeutic linacs
Popis výsledku v původním jazyce
Spectral fluences of neutrons generated in the heads of the radiotherapeutic linacs Varian Clinac 2100 C/D and Siemens ARTISTE were measured by means of the Bonner spheres spectrometer whose active detector of thermal neutrons was replaced by an activation detector, i.e. a tablet made of pure manganese. Measurements with different collimator settings reveal an interesting dependence of neutron fluence on the area defined by the collimator jaws. The determined neutron spectral fluences were used to derive ambient dose equivalent rate along the treatment coach. To clarify at which components of the linac neutrons are mainly created, the measurements were complemented with MCNPX calculations based on a realistic model of the Varian Clinac.
Název v anglickém jazyce
Spectral fluence of neutrons generated by radiotherapeutic linacs
Popis výsledku anglicky
Spectral fluences of neutrons generated in the heads of the radiotherapeutic linacs Varian Clinac 2100 C/D and Siemens ARTISTE were measured by means of the Bonner spheres spectrometer whose active detector of thermal neutrons was replaced by an activation detector, i.e. a tablet made of pure manganese. Measurements with different collimator settings reveal an interesting dependence of neutron fluence on the area defined by the collimator jaws. The determined neutron spectral fluences were used to derive ambient dose equivalent rate along the treatment coach. To clarify at which components of the linac neutrons are mainly created, the measurements were complemented with MCNPX calculations based on a realistic model of the Varian Clinac.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
RADIATION PROTECTION DOSIMETRY
ISSN
0144-8420
e-ISSN
—
Svazek periodika
163
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
373-380
Kód UT WoS článku
000350116700013
EID výsledku v databázi Scopus
—