To what extent can the chosen blood pressure measurement technique affect the outcomes of an observational survey?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064190%3A_____%2F19%3AN0000042" target="_blank" >RIV/00064190:_____/19:N0000042 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/19:10397555 RIV/00669806:_____/19:10397555
Výsledek na webu
<a href="http://dx.doi.org/10.2217/cer-2018-0149" target="_blank" >http://dx.doi.org/10.2217/cer-2018-0149</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2217/cer-2018-0149" target="_blank" >10.2217/cer-2018-0149</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
To what extent can the chosen blood pressure measurement technique affect the outcomes of an observational survey?
Popis výsledku v původním jazyce
Aim: We analyzed to what extent measurement protocol influenced individual blood pressure (BP) and achievement of treatment target in patients with coronary heart disease. Methods: In a subsample of Czech EUROASPIRE III-V survey participants (n = 913), we compared the per-protocol BP measurement (by automated oscillometric device OMRON at the beginning of survey procedure) with control auscultatory measurement (by physician during interview). Results: Per-protocol approach produced significantly (p < 0.0001) higher BP values (by 9/6 mmHg in median) than auscultatory measurements and led to markedly higher proportion of patients over target BP (less than 140/ 90 mmHg; 59.3 vs 34.9% [p < 0.0001], per-protocol vs auscultatory technique, respectively). Conclusion: Per-protocol oscillometric technique was not equivalent to conventional auscultatory measurement and seriously over-rated the real nonachievement of BP target in observational surveys.
Název v anglickém jazyce
To what extent can the chosen blood pressure measurement technique affect the outcomes of an observational survey?
Popis výsledku anglicky
Aim: We analyzed to what extent measurement protocol influenced individual blood pressure (BP) and achievement of treatment target in patients with coronary heart disease. Methods: In a subsample of Czech EUROASPIRE III-V survey participants (n = 913), we compared the per-protocol BP measurement (by automated oscillometric device OMRON at the beginning of survey procedure) with control auscultatory measurement (by physician during interview). Results: Per-protocol approach produced significantly (p < 0.0001) higher BP values (by 9/6 mmHg in median) than auscultatory measurements and led to markedly higher proportion of patients over target BP (less than 140/ 90 mmHg; 59.3 vs 34.9% [p < 0.0001], per-protocol vs auscultatory technique, respectively). Conclusion: Per-protocol oscillometric technique was not equivalent to conventional auscultatory measurement and seriously over-rated the real nonachievement of BP target in observational surveys.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-29520A" target="_blank" >NV17-29520A: Dlouhodobé trendy sekundární prevence ICHS a predikce rizika ve vybraném vzorku české populace - česká část studie EURASPIRE V</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH
ISSN
2042-6305
e-ISSN
2042-6313
Svazek periodika
8
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
841-852
Kód UT WoS článku
000489284500002
EID výsledku v databázi Scopus
2-s2.0-85071739766