Improvement in left ventricular filling properties after relief of right ventricle to pulmonary artery conduit obstruction: contribution of septal motion and interventricular mechanical delay
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F09%3A6006" target="_blank" >RIV/00064203:_____/09:6006 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improvement in left ventricular filling properties after relief of right ventricle to pulmonary artery conduit obstruction: contribution of septal motion and interventricular mechanical delay
Popis výsledku v původním jazyce
In 20 consecutive patients with congenital heart disease and RV to PA conduit obstruction, the following were prospectively assessed before and after percutaneous pulmonary valve implantation (PPVI): the septal curvature and LV volumes throughout the cardiac cycle by magnetic resonance imaging; RV to LV mechanical delay by 2D-echocardiographic strain imaging; and objective exercise capacity. Percutaneous pulmonary valve implantation led to a reduction in RV to LV mechanical delay (127.9+50.9 vs. 37.7+35.6 ms; P , 0.001) and less LV septal bowing in early LV diastole (septal curvature: 20.11+0.11 vs. 0.07+0.13 cm21; P , 0.001). Early LV diastolic filling (first one-third of diastole) increased significantly (17.5+9.4 to 30.4+9.4 mL/m2; P , 0.001). The increase in early LV diastolic filling correlated with the reduction in RV to LV mechanical delay (r 0.25 20.68; P 0.25 0.001) and change in septal curvature (r 0.25 0.71; P , 0.001).
Název v anglickém jazyce
Improvement in left ventricular filling properties after relief of right ventricle to pulmonary artery conduit obstruction: contribution of septal motion and interventricular mechanical delay
Popis výsledku anglicky
In 20 consecutive patients with congenital heart disease and RV to PA conduit obstruction, the following were prospectively assessed before and after percutaneous pulmonary valve implantation (PPVI): the septal curvature and LV volumes throughout the cardiac cycle by magnetic resonance imaging; RV to LV mechanical delay by 2D-echocardiographic strain imaging; and objective exercise capacity. Percutaneous pulmonary valve implantation led to a reduction in RV to LV mechanical delay (127.9+50.9 vs. 37.7+35.6 ms; P , 0.001) and less LV septal bowing in early LV diastole (septal curvature: 20.11+0.11 vs. 0.07+0.13 cm21; P , 0.001). Early LV diastolic filling (first one-third of diastole) increased significantly (17.5+9.4 to 30.4+9.4 mL/m2; P , 0.001). The increase in early LV diastolic filling correlated with the reduction in RV to LV mechanical delay (r 0.25 20.68; P 0.25 0.001) and change in septal curvature (r 0.25 0.71; P , 0.001).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Heart Journal
ISSN
0195-668X
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
18
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000269949200023
EID výsledku v databázi Scopus
—