Re-Evaluation of Cord Blood Arterial and Venous Reference Ranges for pH, pO(2), pCO(2), According to Spontaneous or Cesarean Delivery
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F10%3A6326" target="_blank" >RIV/00064203:_____/10:6326 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/10:6326
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Re-Evaluation of Cord Blood Arterial and Venous Reference Ranges for pH, pO(2), pCO(2), According to Spontaneous or Cesarean Delivery
Popis výsledku v původním jazyce
The aim of this study was to re-evaluate cord blood arterial and venous reference ranges for pH, pO(2), pCO(2) in newborns, delivered by spontaneous vaginal delivery (SVD) and by cesarean section (CS) performed in Faculty Hospital Motol. Two groups of subjects were selected for the study. Group I consisted of 303 newborns with SVD. Group II consisted of 189 newborns delivered by cesarean section. We obtained reference values expressed as range (lower and upper reference value expressed as 2.5 and 97.5 percentiles) for cord blood in newborns with SVD: arterial cord blood: pH = 7.01-7.39; pCO(2) = 4.12-11.45 kPa; pO(2) = 1.49-5.06 kPa; venous cord blood: pH = 7.06-7.44; pCO(2) = 3.33-9.85 kPa; pO(2) = 1.80-6.29 kPa. We also obtained reference values forcord blood in newborns delivered by CS: arterial cord blood: pH = 7.05-7.39; pCO(2) = 5.01-10.60 kPa; pO(2) = 1.17-5.94 kPa; venous cord blood: pH = 7.10-7.42; pCO(2) = 3.88-9.36 kPa; pO(2) = 1.98-7.23 kPa.
Název v anglickém jazyce
Re-Evaluation of Cord Blood Arterial and Venous Reference Ranges for pH, pO(2), pCO(2), According to Spontaneous or Cesarean Delivery
Popis výsledku anglicky
The aim of this study was to re-evaluate cord blood arterial and venous reference ranges for pH, pO(2), pCO(2) in newborns, delivered by spontaneous vaginal delivery (SVD) and by cesarean section (CS) performed in Faculty Hospital Motol. Two groups of subjects were selected for the study. Group I consisted of 303 newborns with SVD. Group II consisted of 189 newborns delivered by cesarean section. We obtained reference values expressed as range (lower and upper reference value expressed as 2.5 and 97.5 percentiles) for cord blood in newborns with SVD: arterial cord blood: pH = 7.01-7.39; pCO(2) = 4.12-11.45 kPa; pO(2) = 1.49-5.06 kPa; venous cord blood: pH = 7.06-7.44; pCO(2) = 3.33-9.85 kPa; pO(2) = 1.80-6.29 kPa. We also obtained reference values forcord blood in newborns delivered by CS: arterial cord blood: pH = 7.05-7.39; pCO(2) = 5.01-10.60 kPa; pO(2) = 1.17-5.94 kPa; venous cord blood: pH = 7.10-7.42; pCO(2) = 3.88-9.36 kPa; pO(2) = 1.98-7.23 kPa.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Clinical Laboratory Analysis
ISSN
0887-8013
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000282486400004
EID výsledku v databázi Scopus
—