Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trc-Cingr cup
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F14%3A10292776" target="_blank" >RIV/00064203:_____/14:10292776 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/14:10292776
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00264-013-2269-7" target="_blank" >http://dx.doi.org/10.1007/s00264-013-2269-7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00264-013-2269-7" target="_blank" >10.1007/s00264-013-2269-7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trc-Cingr cup
Popis výsledku v původním jazyce
Purpose The aim of the present study was to introduce a novel oblong revision cup type TC for use in revision total hip arthroplasty (THA), and to evaluate mid-term results in terms of bone tissue remodelling in the immediate area of the implant. MethodsThe results of 31 patients that underwent revision THA between 2004 and 2008 are presented. The mean follow-up interval was 7.1 years (range 5.3-9.3 years, minimum of five years following revision). Osteointegration of the implant and bone tissue remodelling around the implant and ribs were assessed by X-ray and computed tomography (CT). Results The average Harris hip score increased from 39.8 to 85.3. Excellent results were achieved in nine patients, good in 16, fair in three and poor in three. According to X-ray results, 25 hips had a well-fixed, bone-ingrown cup and five had a stable fibrous union in the middle and the distal third of the implant. Proximal migration of the cup was noted in one case. Pelvic CT was additionally perfor
Název v anglickém jazyce
Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trc-Cingr cup
Popis výsledku anglicky
Purpose The aim of the present study was to introduce a novel oblong revision cup type TC for use in revision total hip arthroplasty (THA), and to evaluate mid-term results in terms of bone tissue remodelling in the immediate area of the implant. MethodsThe results of 31 patients that underwent revision THA between 2004 and 2008 are presented. The mean follow-up interval was 7.1 years (range 5.3-9.3 years, minimum of five years following revision). Osteointegration of the implant and bone tissue remodelling around the implant and ribs were assessed by X-ray and computed tomography (CT). Results The average Harris hip score increased from 39.8 to 85.3. Excellent results were achieved in nine patients, good in 16, fair in three and poor in three. According to X-ray results, 25 hips had a well-fixed, bone-ingrown cup and five had a stable fibrous union in the middle and the distal third of the implant. Proximal migration of the cup was noted in one case. Pelvic CT was additionally perfor
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FI - Traumatologie a ortopedie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Orthopaedics
ISSN
0341-2695
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
935-940
Kód UT WoS článku
000335147900004
EID výsledku v databázi Scopus
—