Nonactivated thromboelastometry able to detect fibrinolysis in contrast to activated methods (EXTEM, INTEM) in a bleeding patient
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F16%3A10332511" target="_blank" >RIV/00064203:_____/16:10332511 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/16:10332511
Výsledek na webu
<a href="http://dx.doi.org/10.1097/MBC.0000000000000479" target="_blank" >http://dx.doi.org/10.1097/MBC.0000000000000479</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MBC.0000000000000479" target="_blank" >10.1097/MBC.0000000000000479</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nonactivated thromboelastometry able to detect fibrinolysis in contrast to activated methods (EXTEM, INTEM) in a bleeding patient
Popis výsledku v původním jazyce
Rotational thromboelastometry (ROTEM) is increasingly used in practice to monitor coagulation status of severely bleeding patients and it helps to provide aimed therapy. The main advantage of ROTEM is detection of fibrinolysis. To get fast results, the reagents for activation, either extrinsic or intrinsic pathway of coagulation, are used. Although this method gives information about whole blood coagulation, in some cases, the patient is bleeding despite normal values of ROTEM. We present a case of a bleeding patient with normal values of activated ROTEM method (EXTEM, INTEM). However, nonactivated method (NATEM) was able to detect fibrinolysis and no clot was found in the cuvette. When tranexamic acid was added to the cuvette, the trace came back to normal value and a clot was formed inside the cuvette. According to this finding, the patient was effectively treated with antifibrinolytic drugs and stopped bleeding. In this case, we want to demonstrate that NATEM, as nonactivated ROTEM, seems to be more sensitive to coagulation changes, especially in detection of fibrinolysis, than activated ROTEM methods.
Název v anglickém jazyce
Nonactivated thromboelastometry able to detect fibrinolysis in contrast to activated methods (EXTEM, INTEM) in a bleeding patient
Popis výsledku anglicky
Rotational thromboelastometry (ROTEM) is increasingly used in practice to monitor coagulation status of severely bleeding patients and it helps to provide aimed therapy. The main advantage of ROTEM is detection of fibrinolysis. To get fast results, the reagents for activation, either extrinsic or intrinsic pathway of coagulation, are used. Although this method gives information about whole blood coagulation, in some cases, the patient is bleeding despite normal values of ROTEM. We present a case of a bleeding patient with normal values of activated ROTEM method (EXTEM, INTEM). However, nonactivated method (NATEM) was able to detect fibrinolysis and no clot was found in the cuvette. When tranexamic acid was added to the cuvette, the trace came back to normal value and a clot was formed inside the cuvette. According to this finding, the patient was effectively treated with antifibrinolytic drugs and stopped bleeding. In this case, we want to demonstrate that NATEM, as nonactivated ROTEM, seems to be more sensitive to coagulation changes, especially in detection of fibrinolysis, than activated ROTEM methods.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FD - Onkologie a hematologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Blood Coagulation & Fibrinolysis
ISSN
0957-5235
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
3
Strana od-do
828-830
Kód UT WoS článku
000385529500016
EID výsledku v databázi Scopus
2-s2.0-84949571204