Outcomes in anticoagulated patients with atrial fibrillation and with mitral or aortic valve disease
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F18%3A10378535" target="_blank" >RIV/00064203:_____/18:10378535 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1136/heartjnl-2017-312272" target="_blank" >https://doi.org/10.1136/heartjnl-2017-312272</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1136/heartjnl-2017-312272" target="_blank" >10.1136/heartjnl-2017-312272</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Outcomes in anticoagulated patients with atrial fibrillation and with mitral or aortic valve disease
Popis výsledku v původním jazyce
Objective To assess stroke/systemic embolism, major bleeding and other outcomes, and treatment effect of apixaban versus warfarin, in patients with atrial fibrillation (AF) and different types of valvular heart disease (VHD), using data from the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation trial. Methods There were 14 793 patients with known VHD status, categorised as having moderate or severe mitral regurgitation (MR) (n=3382), aortic regurgitation (AR) (n=842) or aortic stenosis (AS) (n=324); patients with moderate or severe mitral stenosis were excluded from the trial. Baseline characteristics, efficacy and safety outcomes were compared between each type and no significant VHD. Treatment effect was assessed using an adjusted model. Results Patients with MR or AR had similar rates of stroke/systemic embolism and bleeding compared with patients without MR or AR, respectively. Patients with AS had significantly higher event rates (presented as rate per 100 patient-years of follow-up) of stroke/systemic embolism (3.47 vs 1.36; adjusted HR (adjHR) 2.21, 95% CI 1.35 to 3.63), death (8.30 vs 3.53; adjHR 1.92, 95% CI 1.41 to 2.61), major bleeding (5.31 vs 2.53; adjHR 1.80, 95% CI 1.19 to 2.75) and intracranial bleeding (1.29 vs 0.51; adjHR 2.54, 95% CI 1.08 to 5.96) than patients without AS. The superiority of apixaban over warfarin on stroke/systemic embolism was similar in patients with versus without MR (HR 0.69, 95% CI 0.46 to 1.04 vs HR 0.79, 95% CI 0.63 to 1.00; interaction P value 0.52), with versus without AR (HR 0.57, 95% CI 0.27 to 1.20 vs HR 0.78, 95% CI 0.63 to 0.96; interaction P value 0.52), and with versus without AS (HR 0.44, 95% CI 0.17 to 1.13 vs HR 0.79, 95% CI 0.64 to 0.97; interaction P value 0.19). For each of the primary and secondary efficacy and safety outcomes, there was no evidence of a different effect of apixaban over warfarin in patients with any VHD subcategory. Conclusions In anticoagulated patients with AF, AS is associated with a higher risk of stroke/systemic embolism, bleeding and death. The efficacy and safety benefits of apixaban compared with warfarin were consistent, regardless of presence of MR, AR or AS.
Název v anglickém jazyce
Outcomes in anticoagulated patients with atrial fibrillation and with mitral or aortic valve disease
Popis výsledku anglicky
Objective To assess stroke/systemic embolism, major bleeding and other outcomes, and treatment effect of apixaban versus warfarin, in patients with atrial fibrillation (AF) and different types of valvular heart disease (VHD), using data from the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation trial. Methods There were 14 793 patients with known VHD status, categorised as having moderate or severe mitral regurgitation (MR) (n=3382), aortic regurgitation (AR) (n=842) or aortic stenosis (AS) (n=324); patients with moderate or severe mitral stenosis were excluded from the trial. Baseline characteristics, efficacy and safety outcomes were compared between each type and no significant VHD. Treatment effect was assessed using an adjusted model. Results Patients with MR or AR had similar rates of stroke/systemic embolism and bleeding compared with patients without MR or AR, respectively. Patients with AS had significantly higher event rates (presented as rate per 100 patient-years of follow-up) of stroke/systemic embolism (3.47 vs 1.36; adjusted HR (adjHR) 2.21, 95% CI 1.35 to 3.63), death (8.30 vs 3.53; adjHR 1.92, 95% CI 1.41 to 2.61), major bleeding (5.31 vs 2.53; adjHR 1.80, 95% CI 1.19 to 2.75) and intracranial bleeding (1.29 vs 0.51; adjHR 2.54, 95% CI 1.08 to 5.96) than patients without AS. The superiority of apixaban over warfarin on stroke/systemic embolism was similar in patients with versus without MR (HR 0.69, 95% CI 0.46 to 1.04 vs HR 0.79, 95% CI 0.63 to 1.00; interaction P value 0.52), with versus without AR (HR 0.57, 95% CI 0.27 to 1.20 vs HR 0.78, 95% CI 0.63 to 0.96; interaction P value 0.52), and with versus without AS (HR 0.44, 95% CI 0.17 to 1.13 vs HR 0.79, 95% CI 0.64 to 0.97; interaction P value 0.19). For each of the primary and secondary efficacy and safety outcomes, there was no evidence of a different effect of apixaban over warfarin in patients with any VHD subcategory. Conclusions In anticoagulated patients with AF, AS is associated with a higher risk of stroke/systemic embolism, bleeding and death. The efficacy and safety benefits of apixaban compared with warfarin were consistent, regardless of presence of MR, AR or AS.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart
ISSN
1355-6037
e-ISSN
—
Svazek periodika
104
Číslo periodika v rámci svazku
15
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1292-1299
Kód UT WoS článku
000442379200014
EID výsledku v databázi Scopus
2-s2.0-85049136248