Effect of impaired cardiac conduction after alcohol septal ablation on clinical outcomes: Insights from the Euro-ASA registry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F19%3A10395613" target="_blank" >RIV/00064203:_____/19:10395613 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/19:00112991 RIV/00216208:11130/19:10395613 RIV/00159816:_____/19:00072502
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oK0wuh4odB" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oK0wuh4odB</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ehjqcco/qcy049" target="_blank" >10.1093/ehjqcco/qcy049</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of impaired cardiac conduction after alcohol septal ablation on clinical outcomes: Insights from the Euro-ASA registry
Popis výsledku v původním jazyce
Aims: We analysed the impact of bundle branch block (BBB) and pacemaker (PM) implantation on symptoms and survival after alcohol septal ablation (ASA) in patients with hypertrophic cardiomyopathy (HCM). Methods and results: Among 1416 HCM patients from the Euro-ASA registry, 58 (4%) patients had a PM and 64 (5%) patients had an implantable cardioverter-defibrillator (ICD) before ASA. At latest follow-up (5.0 +- 4.0 years) after ASA, 118 (8%) patients had an ICD and 229 (16%) patients had a PM. In patients without an implantable device prior to ASA 13% had a PM and 5% had an ICD implanted following ASA. New onset BBB was present in 44% (right BBB in 31%) of patients without previous BBB. At latest follow-up, we found no associations between BBB and New York Heart Association (NYHA) Class 3-4 [odds ratio (OR) 0.98, 95% confidence interval (CI) 0.63-1.51; P = 0.91] or Canadian Cardiovascular Society (CCS) Class 3-4 (OR 1.5, CI 0.32-6.7; P = 0.62), respectively, and no associations between PM and NYHA Class 3-4 (OR 1.2, CI 0.70-2.0; P = 0.52) or CCS 3-4 (OR 1.3, CI 0.24-6.6; P = 0.79), respectively. The survival after ASA was not reduced in patients with BBB [hazard ratio (HR) 0.73, CI 0.53-1.01; P = 0.06] or PM (HR 0.78, CI 0.52-1.17; P = 0.24). Conclusions: Development of BBB or need for a PM after ASA in patients with obstructive HCM was not associated with inferior symptomatic outcome or reduced survival, thus concerns for the negative impact of impaired cardiac conduction on the clinical outcome after ASA were not confirmed.
Název v anglickém jazyce
Effect of impaired cardiac conduction after alcohol septal ablation on clinical outcomes: Insights from the Euro-ASA registry
Popis výsledku anglicky
Aims: We analysed the impact of bundle branch block (BBB) and pacemaker (PM) implantation on symptoms and survival after alcohol septal ablation (ASA) in patients with hypertrophic cardiomyopathy (HCM). Methods and results: Among 1416 HCM patients from the Euro-ASA registry, 58 (4%) patients had a PM and 64 (5%) patients had an implantable cardioverter-defibrillator (ICD) before ASA. At latest follow-up (5.0 +- 4.0 years) after ASA, 118 (8%) patients had an ICD and 229 (16%) patients had a PM. In patients without an implantable device prior to ASA 13% had a PM and 5% had an ICD implanted following ASA. New onset BBB was present in 44% (right BBB in 31%) of patients without previous BBB. At latest follow-up, we found no associations between BBB and New York Heart Association (NYHA) Class 3-4 [odds ratio (OR) 0.98, 95% confidence interval (CI) 0.63-1.51; P = 0.91] or Canadian Cardiovascular Society (CCS) Class 3-4 (OR 1.5, CI 0.32-6.7; P = 0.62), respectively, and no associations between PM and NYHA Class 3-4 (OR 1.2, CI 0.70-2.0; P = 0.52) or CCS 3-4 (OR 1.3, CI 0.24-6.6; P = 0.79), respectively. The survival after ASA was not reduced in patients with BBB [hazard ratio (HR) 0.73, CI 0.53-1.01; P = 0.06] or PM (HR 0.78, CI 0.52-1.17; P = 0.24). Conclusions: Development of BBB or need for a PM after ASA in patients with obstructive HCM was not associated with inferior symptomatic outcome or reduced survival, thus concerns for the negative impact of impaired cardiac conduction on the clinical outcome after ASA were not confirmed.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Heart Journal: Quality of Care and Clinical Outcomes
ISSN
2058-5225
e-ISSN
—
Svazek periodika
5
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
252-258
Kód UT WoS článku
000493732200013
EID výsledku v databázi Scopus
2-s2.0-85068919842