Pediatric catheter ablation at the beginning of the 21st century: results from the European Multicenter Pediatric Catheter Ablation Registry 'EUROPA'
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F21%3A10418065" target="_blank" >RIV/00064203:_____/21:10418065 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/21:10418065
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WUaEelXh2g" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WUaEelXh2g</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euaa325" target="_blank" >10.1093/europace/euaa325</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pediatric catheter ablation at the beginning of the 21st century: results from the European Multicenter Pediatric Catheter Ablation Registry 'EUROPA'
Popis výsledku v původním jazyce
AIMS: Contemporary data from prospective multicentre registries on catheter ablation in pediatric patients are sparse. Aim of the European Pediatric Catheter Ablation Registry EUROPA was to contribute data to fill this gap of knowledge. METHODS AND RESULTS: From July 2012 to June 2017, data on catheter ablation in pediatric patients (<=18 years of age) including a 1-year follow-up from five European pediatric EP centres were collected prospectively. A total of 683 patients (mean age 12.4 +- 3.9 years, mean body weight 50.2 +- 19 kg) were enrolled. Target tachycardia was WPW/atrioventricular-nodal re-entrant tachycardia (AVRT) in 380 (55.7%) patients, AVNRT in 230 (33.8%) patients, ventricular tachycardia (VT) in 24 (3.5) patients, focal atrial tachycardia (FAT) in 20 (2.9%) patients, IART in 14 (2%) patients, and junctional ectopic tachycardia in 3 (0.45) patients. Overall procedural success was 95.6%. Compared with all other substrates, success was significantly lower in FAT patients (80%, n = 16, P = 0.001). Mean procedure duration was 136 +- 67 min and mean fluoroscopy time was 4.9 +- 6.8 min. Major complications occurred in 0.7% of the patients. No persisting AV block requiring permanent pacing was reported. At 1-year follow-up (605/683 patients, 95%), tachycardia recurrence was reported in 7.8% of patients. Recurrence after VT ablation (33%) was significantly higher (P = 0.001) than after ablation of all other substrates. CONCLUSION: The present study proves overall high efficacy and safety of catheter ablation of various tachycardia substrates in pediatric patients. Of note, complication rate was exceptionally low. Long-term success was high except for patients after VT ablation.
Název v anglickém jazyce
Pediatric catheter ablation at the beginning of the 21st century: results from the European Multicenter Pediatric Catheter Ablation Registry 'EUROPA'
Popis výsledku anglicky
AIMS: Contemporary data from prospective multicentre registries on catheter ablation in pediatric patients are sparse. Aim of the European Pediatric Catheter Ablation Registry EUROPA was to contribute data to fill this gap of knowledge. METHODS AND RESULTS: From July 2012 to June 2017, data on catheter ablation in pediatric patients (<=18 years of age) including a 1-year follow-up from five European pediatric EP centres were collected prospectively. A total of 683 patients (mean age 12.4 +- 3.9 years, mean body weight 50.2 +- 19 kg) were enrolled. Target tachycardia was WPW/atrioventricular-nodal re-entrant tachycardia (AVRT) in 380 (55.7%) patients, AVNRT in 230 (33.8%) patients, ventricular tachycardia (VT) in 24 (3.5) patients, focal atrial tachycardia (FAT) in 20 (2.9%) patients, IART in 14 (2%) patients, and junctional ectopic tachycardia in 3 (0.45) patients. Overall procedural success was 95.6%. Compared with all other substrates, success was significantly lower in FAT patients (80%, n = 16, P = 0.001). Mean procedure duration was 136 +- 67 min and mean fluoroscopy time was 4.9 +- 6.8 min. Major complications occurred in 0.7% of the patients. No persisting AV block requiring permanent pacing was reported. At 1-year follow-up (605/683 patients, 95%), tachycardia recurrence was reported in 7.8% of patients. Recurrence after VT ablation (33%) was significantly higher (P = 0.001) than after ablation of all other substrates. CONCLUSION: The present study proves overall high efficacy and safety of catheter ablation of various tachycardia substrates in pediatric patients. Of note, complication rate was exceptionally low. Long-term success was high except for patients after VT ablation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Europace
ISSN
1099-5129
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
431-440
Kód UT WoS článku
000637048400016
EID výsledku v databázi Scopus
2-s2.0-85102908834